Download Print this page

Lcd Screen And Settings; Initial Operation - TZS First AUSTRIA FA-2461-2-WI Instruction Manual

Weather forecast station

Advertisement

Available languages

Available languages

FEATURES:
Time in optional 12/24 hour format.
Date and weekday display
Continuous calendar up to 2099
Two daily alarms
Automatic snooze function
Barometer: Graphic display to show the air
pressure, display either in mb/hPa or inHg, air
pressure trend display
• Weather forecast using five icons: sunny, light
cloud cover, cloudy, rain and stormy
• Temperature alternatively in°C or°F
Temperature cozy icon display.
Thermometer:
Indoor measurement ranges: 0°C (32°F) ~
50°C (122°F) (calibration time: 30 seconds),
outdoor measurement ranges: -22°C (-3.8°F)
~ 50°C (122°F) (calibration time: 30 seconds),
Hygrometer: Measurement range: 20%-95% .
Minimum/maximum display for air humidity
and temperature
Temperature alert
Moon phase display.
• LED back light display (auto off after 8
seconds in battery powered, DC power
supply has always been).
Power Supply:
Weather Station:
Battery: 2 x LR6 AA
DC-POWER: DC 4.5V 200mA
Wireless Outdoor Sensor:
Battery: 2 x LR6 AA

LCD SCREEN AND SETTINGS:

(Fig A)
1. Air pressure icon
2. Weather forecast
3. Air pressure time history
4. Histogram shows the trend of 12 hours of
atmospheric pressure
5. Air pressure values
6. Time
7. SNOOZE icon
8. Temperature alert
9. Cozy icon
10. RF icon
11. Channel cycle
12. Indoor temperature values
13. Indoor temperature trend
14. Main unit low battery icon
15. Indoor humidity trend
16. Indoor humidity values
17. Outdoor temperature trend
18. Outdoor sensor low battery icon
19. Outdoor humidity trend
20. Outdoor humidity values
21. Outdoor temperature values
22. Moon phase icon
23. Week
24. Date
25. Alarm icon
26. Channel selection
Main Unit Structure function description
(Fig B)
a) SNOOZE/LIGHT functional touch area
b) Button operation panel
c) Insertion position of power supply
d) Battery mount position
WIRELESS OUTDOOR SENSOR (Fig C)
C1: LCD display – Temperature
C2: LCD display – Humidity
C3: LCD display – RF icon
C4: LED icon by RF
C5: "C°/F°" button
C6: "TX" button
C7: Battery compartment
Wireless remote sensor (transmitter)
Transmitter frequency: 433.92 MHz.
Range of transmission is up to 60m
(200 feet).
Insert the 2 batteries in to the transmitter. Pay
attention to observe the correct polarity.

INITIAL OPERATION:

Open Weather Station battery compartment
cover
• Insert 2 x AA batteries observing polarity [ "+"
and " –" marks]
When you insert the batteries, all the icon
on the LCD display will briefly light up for 3
seconds, and you will hear a beep tone, and
detect indoor temperature & humidity.
The Weather Station will now start to make
a connection to the outdoor remote sensor.
This operation takes about 3 minutes and is
displayed by a flashing reception RF antenna
symbol in the "OUT" display area on the
receiver.
This now, replace Wireless Outdoor Sensor
battery compartment cover. Open Weather
Station battery compartment cover. Insert 2
x AA batteries observing polarity [ "+" and "–"
marks]
• After receiver has created a connection to the
outdoor remote sensor, it will then b enters
the clock mode.
MANUAL TIME SETTING:
• Press and hold down the "SET/HISTORY"
button for two seconds.
• The year display "2012" starts to flash. Now
use "UP" and "DOWN/" to set the correct
year.
• Press "SET/HISTORY" to confirm your
setting.
• The month display starts to flash. Now use
"UP" and "DOWN/" to set the correct month
2
• Press "SET/HISTORY" to confirm your
setting.
• The date display starts to flash. Now use
"UP" and "DOWN/" to set the correct date.
• Press "SET/HISTORY" to confirm your
setting.
There are 7 languages of Weekday: German,
English, Italian, French, Dutch, Spanish, and
Danish, press "UP" and "DOWN/" to select.
• Press "SET/HISTORY" to confirm your
setting.
The time is displayed either in 12 or 24
hour format. Briefly pressing the "UP" and
"DOWN/" button allows you to switch
between the individual modes. The symbol
AM (before midday) or PM (after midday)
appears after the time.
• Press "SET/HISTORY" to confirm your
setting.
• The hour display starts to flash. Now use
"UP" and "DOWN/" to set the correct hour.
• Press "SET/HISTORY" to confirm your
setting.
• The minute display starts to flash. Now
use "UP" and "DOWN/" to set the correct
minute.
• Press "SET/HISTORY" to confirm your
setting.
• The Time zones start to flash, Now use "UP"
and "DOWN/" buttons to set a correct time
zone (-12 to +12).
• Press "SET/HISTORY" to confirm your
setting.
• The weather icon display starts to flash. Now
use "UP" and "DOWN/" to set the weather
of the day
• Press "SET/HISTORY" to confirm your
setting.
• The air pressure unit display starts to flash.
Now use "UP" and "DOWN/" to calibrate
current air pressure deviation
• Press "SET/HISTORY" to confirm your
setting.
• The air pressure unit display starts to flash.
Now use "UP" and "DOWN/" to set the mb/
hPa or in Hg
SETTING THE DAILY ALARMS:
The weather station possesses has two daily
alarms. To view the set alarm times, press
the "ALARM/SET" button briefly. The display
switches from the clock to Alarm 1 and, if you
press the button again, to Alarm 2. (In eight
seconds, the weather stations automatically
return to the normal time display.)
Proceed as follows to set the daily alarm:
• Press and hold down the "ALARM/SET"
button for two seconds until alarm time 1 and
the flashing icon are displayed.
• Now use the "UP" and "DOWN/" buttons
to select the alarm time you require and then
briefly press the "ALARM/SET" button to set
this time.
The hour display of the alarm time starts
to flash. Use the arrow keys "UP" and
"DOWN/" buttons to set the required hour.
• Press "ALARM/SET" to confirm your setting
The minute display of the alarm time starts
to flash. Use the arrow keys "UP" and
"DOWN/" to set the required minute.
• Press "ALARM/SET" to confirm your setting
and to end the setting procedure.
Activation and deactivating the daily alarms:
• To activate or deactivate the daily alarms,
briefly press the "DOWN/" button:
Press 1x: Alarm 1 activated
Press 2x: Alarm 2 activated
Press 3x: Both alarms are activated
Press 4x: Both alarms deactivated
Information:
After eight seconds without a button being
pressed, the clock switches automatically
from setting mode to Normal clock mode.
The alarm will sound for two minutes if you
do not deactivate it by pressing any button.
In this case, the alarm will be repeated
automatically after 24 hours.
• Rising alarm (length: 2 minutes) changes the
volume four times whilst the alarm signal is
heard.
• Press "SET/HISTORY" or "ALARM/SET"
button to deactivate the alarm.
Automatic snooze function
• Proceed as follows to activate the automatic
snooze function:
While the alarm is sounding, press touch the
"LIGHT/SNZ" to activate the snooze function.
When the snooze function is active, the "Zz"
symbol appears in the display.
• This operation moves the alarm back by five
minutes and the alarm will restart at this time
The snooze function can be interrupted by
pressing any button or repeated up to seven
times
• Press "SET/HISTORY" or "ALARM" button to
deactivate the snooze function.
°C/°F temperature display
• The temperature is displayed either in °C/°F.
Briefly pressing the °C/°F button allows you to
switch between the individual modes.
Temperature trend display
After you insert the batteries, the weather station
measures the current temperature. The trend
3

Advertisement