11.2. Indoor Unit

11.2.1. How To Fix Installation Plate
The mounting wall shall be strong and solid enough to prevent it from the vibration.
The centre of installation plate should be at more than
The distance from installation plate edge to ceiling should more than
From installation plate left edge to unit's left side is
From installation plate right edge to unit's right is
:For left side piping, piping connection for liquid should be about
:For left side piping, piping connection for gas should be about
1. Mount the installation plate on the wall with 5 screws or more (at least 5 screws).
(If mounting the unit on the concrete wall, consider using anchor bolts.)
• Always mount the installation plate horizontally by aligning the marking-off line with the thread and using a level gauge.
2. Drill the piping plate hole with ø70 mm hole-core drill.
• Putting measuring tape at position as shown in the diagram above.
The hole center is obtained by measuring the distance namely 128 mm for left and right hole respectively. Another method is
intersection point of arrow mark extension.
The meeting point of the extension arrow mark is the hole center position.
• Drill the piping hole at either the right or the left and the hole should be slightly slanting to the outdoor side. (refer to step
11.2.2)
11.2.2. To Drill A Hole In The Wall And Install A Sleeve Of Piping
1. Insert the piping sleeve to the hole.
2. Fix the bushing to the sleeve.
3. Cut the sleeve until it extrudes about 15 mm from the
wall.
4. Finish by sealing the sleeve with putty or caulking
compound at the final stage.
at right and left of the wall.
.
.
.
from this line.
from this line.