  • Page 1 Sakura Air Conditioner User-friendly, Earth-friendly Manual R-410a Installation, Operation & Maintenance Sakura Water Source Heat Pump (package)   (SSR-L/J-009 ~ 072) Ref, S- 177 / 07 / 11...
  • Page 2: Installation

    A flat washer and two nuts (not supplied by Note: The unit is shipped from the factory with access to Sakura) should be used to mount the unit on the ceiling- the electrical box such that return air enters the unit from attached threaded rods.
  • Page 3 Figure 1: Horizontal mounting detail (L009-J072H) NOTES 1)USE A BACKUP WRENCH ON FITTINGS WHEN MAKING WATER CONNECTIONS 2)DO NOT SCREW DUCTWORK INTO THE HEAT PUMP CABINET USE THE FLANGES PROVIDED ON FIL TER GUIDES AND BLOWER HANGER RODS OPENING。 (BY OTHERS) SEE GROMMET DETAIL ELECTRICAL ACCESS (SEE FIGURE 2)
  • Page 4 Figure 4:Horizontal mounting detail (J086~142H) VIBRATION ISOLATION GROMMET (SEE FIGURE 5) Figure 5: Grommet detail THREADED ROD (BYOTHERS) HANGER BRACKET VIBRATION ISOLATION GROMMET WASHER(BYOTHERS) MUST COVER ENTIRE BOTTOM OF GROMMET RETAINING NUTS (BYOTHERS) Figure 6:Installation space requirement (Dimensions in mm) This drawing is for left hand piping unit Filter length Filter length...
  • Page 5: Water Supply

    Do not 1" Min. Internal Trap use wrench on hose or on the sleeve that crimps the fitting onto (By Sakura) the hose. Hoses must not be pulled taut, twisted or kinked. Connections should not be over tightened.
  • Page 6 Figure 9: Discharge conversion(009-142) Discharge Conversion – Horizontal Unit All horizontal unit sizes from 009H to 072H can be field-converted from straight discharge to side discharge. 1. Set the unit on a level surface. 2. Remove blower access panel. 3. Remove top panel. 4.
  • Page 7: Operation

    After installing, connecting ductwork and condensate lines and wiring, unit is ready for startup. Check all internal wire Sakura heat pumps have been designed with switches that connections and connections to external control devices. protect the unit’s refrigerant system. They will automatically...
  • Page 8: Electrical Specification

    Electrical specification Electrical Service and Fusing Warning: To avoid severe electrical shock, turn off power before servicing controls. Unit must be installed in compliance with local codes. Route power wires through a properly sized disconnect switch. Consult the wiring diagrams inside the cover of the electrical box to complete the connection.
  • Page 9 Dry contact OUT7 Hign fan speed Dry contact OUT10 4-Way valve 1 Dry contact OUT11 Compressor 1 Dry contact OUT12 Electrical heater Dry contact SAKURA CORPORATION Tel: (81)45-949-8550 Fax: (81)45-949-8551 E-mail: mail@sakura-aircon.com URL: www.sakura-aircon.com 2-17-1. Eda-minami, Tsuzuki-ku, Yokohama, Kanagawa, 224-0007, Japan...