Econar GeoSurce Vara 2 Plus GV Series Lnstallation And Operating Lnstructions page 9

Vertical and horizontal forced air
Table of Contents

Advertisement

Frcm
E4miu
T{Dk
Shrof
Valve
Stroie
Vituii
FLow
Meto
Boila
Drais
IN
otT
Solooid
Valve
Flow
Conkol
Valvo
Prsme/
T@paatre
(P/T)
Pdts
f
Disobugr
\J
Figure
3
-
Open Loop
Water Plumbing
Schedule
40 PVC
piping,
copper tubing, polyethylene
or
rubber
hose can be used
for
supply
and
discharge water
lines.
Make
sure
line
sizes are
large
enough
to supply
the
requfued
flow
with
a
reasonable pressure
drop (generally
l"
diameter
minimum).
Water
discharge
is generally
made
to
a
drain
field,
stream,
pond,
sudace
discharge,
tile line, or
storm
sewer.
VCAUTION:
Using
a
drain
field
requires
soil
conditions
and adequate
sizing
to
assure
rapid percolation,
or
the
required
flow
rates
will
not
be
achieved.
Consult
local
codes and ordinances
to
assure
compliance.
D0
pf,
discharge the
water
into
a
septic
system.
The
heat
pump should
never be operated
with
flow
rates
less
than
specified.
Low flow
rates
or
no
flow
may result
in
freezing water
in
the
water to refrigerant
heat
exchanger.
This
will
cause
the
unit
to
shut
down on
freeze
protection (FP)
lockout.
Ifthe
unit
locks out,
verify
that
the
unit
has the
required
flow
and reset the
unit
by
shutting
offpower
to
the
unit for
one
minute.
VDO
![Qf,
reset the
unit;
if
the
unit
locks out more than
once
call your
service
professional.
EContinued
reset
of
the
unit
can
freeze
water inside the water
coil
to
the
point
of
rupfudng
the
water
coil.
1.
Open Loop Freeze Protection Switch
Heat pump installations
on open
loop
systems,
using
a
non-antifreeze protected water
source
during
the
heating
mode,
require
the
use
of
freeze
protection
switches.
If
the
water supply to
the heat
pump is interrupted
for
any
reason,
continued operation
of
the
compressor
would
cause
the
water remaining
in
the water-to-refrigerant
heat
exchanger
to
freeze
and
rupture
the heat
exchanger.
The
freeze
protection
switch (ECONAR
Part
#
75-i045)
will
shut the
unit
down before freezing
can
occur
and
protect
the heat
pump
against loss
of
flow.
A FREEZE
PROTECTION SWITCH MUST
BEFIELD
INSTALLED
ON
OPEN
LOOP
GeoSource
Vara
2
prus'*
HEAT
puMps
BEFORE
TrrE
wARRANTy
CAN BE REGISTERED
ON
THE HEAT
PUMP.
This
switch mounts on
the
compressor's suction
line
and is
wired
to terminals on
the
controller (from
X
to
FP).
This
low
pressure
switch now locks
the
unit
off
at 65
psi
pressure
in
the
heating
mode.
2.
Water Coil Maintenance
Water
quality
is
a
major concern
for
open systems.
Problems
can
occur
from
scaling, particle
buildup,
suspended
solids, corrosion,
pH
levels outside
thel-9
range,
or
biological
growth.
If
poor water
quality
is
known
to exist
in your
area,
a
closed loop may
be the best
application.
Water
coil
cleaning on
an open
loop
system
may
be necessary
on
a
regular
basis.
Depending
on the
specific water
quality
issue, the
water
coil
can be cleaned
by
the
following
methods:
a.
Freeze
Cleaning
(Scale deposits,
particle
buildup)
I.
Before using
the freeze
cleaning procedure,
verify
that
it
needs to be
done.
Answer
the
following
questions to
determine
if
servicing is required.
1.
Determine
and
verify
that
the
required water
flow
rate
in GPM
is
both present
and
correct.
2.
Determine
the
temperafure
differential of
the
1