COOLING SYSTEM
Type
Water Pump:
Type
Drive
Belt Deflection
Fan Diameter
Number of Fan Blades
Thermostat:
Start to Open
Fully Open
Radiator Cap
Antifreeze
System Capacity
ELECTRICAL SYSTEM
Main System Protection
Number Fuses for Circuit Protection
Alternator
Battery Type
Starter Motor - Type
Starter KW(HP) Rating
Bulb Rating and Type
FUEL SYSTEM
Fuel Type
Type of Fuel to Use if above 5 °C (40
°F)
Type of Fuel to Use if below 5 °C (40
°F)
Injection Pump:
Type
Timing
INTRODUCTION
WORKMASTER 45
Pressurized Liquid with Recirculating
Bypass
Centrifugal
V-Belt
10 - 15 mm (0.4375 - 0.5625 in)
when 9 - 11 kg (20 - 25 lb) thumb
pressure is applied midway between
belt pulleys
410 mm (16.1 in)
6
71 °C (160 °F)
82 °C (180 °F)
90 kPa (13 psi)
Ethylene Glycol
8.5 l (9.0 US qt)
Fusible Link ( 20 A)
6
12 V, 40 A
12 V, w/ negative ground, 600-850
cca
BCI group 49
Solenoid operated
2.0 kW (2.7 Hp)
Head Light 35/ 35 W
Turn Signal 27 W/#1156
Tail Light 8.5 W/#1157
Diesel
No. 2-Diesel, Cetane Rating:
Minimum 45
No. 1-Diesel, Cetane Rating:
Minimum 45
In-Line CTD
19 - 20.5 ° BTDC
_84269847_ 16/04/2010
Pressurized Liquid with Recirculating
Bypass
Centrifugal
V-Belt
10 - 15 mm (0.4375 - 0.5625 in)
when 9 - 11 kg (20 - 25 lb) thumb
pressure is applied midway between
belt pulleys
410 mm (16.1 in)
8
71 °C (160 °F)
82 °C (180 °F))
90 kPa (13 psi)
Ethylene Glycol
8.5 l (9.0 US qt)
Fusible Link ( 20 A)
6
12 V, 40 A
12 V, w/ negative ground, 600-850
cca
BCI group 49
Solenoid operated
2.0 kW (2.7 Hp)
35/ 35 W
27 W/#1156
8.5 W/#1157
Diesel
No. 2-Diesel, Cetane Rating:
Minimum 45
No. 1-Diesel, Cetane Rating:
Minimum 45
In-Line CTD
17.5 - 19 ° BTDC
18
WORKMASTER 55