SCROLL AXIAL HEAT PUMPS - Technical - Installation manual ANL 100-150HA HEAT PUMP • EXTERNAL UNIT 60Hz • HIGH EFFICENCY • HOT WATER PRODUCING UP TO 122°F / 50°C • POWER SUPPLY 60Hz IANL60HzPY. 1205. 6755517_02...
Page 3
AERMEC S.p.A AERMEC S.p.A. reserves the right at any moment to make any modifications considered necessary to improve our products and is not obliged to add these modifications to machines that have already been fabricated, delivered or are under construction.
INDeX Description and choce of unit............6 Dimensions .................29 anl 100 - 150 H|Hp|Ha version ........... 29 21.1. Product identification ..............6 Antivibration positioning and distribution of percentage on supporting points ..............29 Ceck list ..................6 Configurator .................7 Hydraulic connections ..............30 Main cooling layout ..............8 Electrical data ................31 24.1.
DeSCrIPtIoN AND CHoCe oF UNIt Standards and Directives respected on desi- gning and constructing the unit: Chillers and heat pumps for outdoor condensed in ANL "°" Standard ProteCtIoN rAtINg the air with R410A Series ANL have been designed ANL "H" Heat pumps IP 24 and manufactured to satisfy heating and cooling needs and the production of domestic hot water...
CoNFIgUrAtor FIELD CODE 1, 2 ,3 4, 5, 6 SIZE 100 -150 MODEL heat pump VErsion ° standard with pump with storage tank and pump HEaT rECoVEry without heat recovery units ° COILS in aluminium ° FIELD OF USE temperature of water produced up to 39.2°F / +4°C °...
OnE-WAY VALVES DeSCrIPtIoN oF CoMPoNeNtS Allows the passage of the refrigerant in just one direction. 6.1. CHILLer CIrCUIt LIqUID STOrAGE TAnK SCROLL COMPRESSORS Compensates the difference in volume betwe- High efficiency scroll-type hermetic com- en louveres coil and plate exchanger, withhol- pressors, assembled on elastic antivibration ding excess liquid.
of water to be sent to the utilities. Electric regolation MoDU CoNtroL 6.5. SAFetY AND CoNtroL CoMPoNeNtS Temperature control of the output water with proportional-integral HIgH PreSSUre SwItCH algorithm: maintains average output temperature at value set With fixed calibration, placed on high pressure - Self-adapting differential switch: guarantees minimum functioning side of cooling circuit, inhibits functioning of times of the compressor in systems with low water content.
220-3-60 171,00 198,40 Load 25% air 12,8°C / 55,04°F HP-HA 460-3-60 83,40 97,50 220-3-60 51,30 60,60 SoUND Power Aermec determines sound power values in agree- 460-3-60 25,50 31,80 ment with the 9614-2 Standard. HP-HA 220-3-60 54,90 66,80 HP-HA 460-3-60 27,50...
Page 13
Load 50% air 18,3°C / 64,94°F Depth Load 25% air 12,8°C / 55,04°F Weight SoUND Power Aermec determines sound power values in agree- ment with the 9614-2 Standard. SoUND PreSSUre Sound pressure measured in free field conditions with reflective surface (directivity factor q=2) at 394 in/10mt distance from external surface of unit, in compliance with ISO 3744 regulations.
oPerAtINg LIMItS The devices in their standard configuration, are not Wind breaks should be implemented if the unit is suitable for installation in a saline environment. To the installed in particularly windy areas, to prevent a limits of operation, please refer to the diagram, valid for malfunction of the unit.
etHYLeNe gLYCoL SoLUtIoNS • The correction factors of cooling power ∆P (1) and input power take into account the 2.20 ∆P (2) presence of glycol and diverse evapora- 2. 1 0 2.00 tion temperatures. ∆P (3) 1.90 • The pressure drop correction factor ∆P (4) 1.80 considers the different flow rate resulting...
PreSSUre DroP 13.1. SYSTEM SIDE - PrESSUrE DrOP OnLY COOLInG VErSIOn CooLINg (AHrI CoNDItIoNS) 11.60 Outlet water temperature 6,7°C / 44,6°F Flow rate 0,043l/s per kW External temperature 35°C / 95°F 10.15 8.70 For temperatures other than 50°F / 10°C to use the table of correction factors.
USeFUL HeADS The static pressures stated here are at net − − The static pressures are calculated in WITH PRESENCE OF GLYCOL for static of the pressure drops of the heat exchang- cooling mode. pressures useful to system PLEASE ers, filter, storage tank. Therefore are to be CONTACT COMPANY.
15. STOrAGE TAnK AnL 100-150 ≥ 12.25 Hydraulic height The following tables highlight principle char- Calibration of expansion vessel acteristics for hydraulic circuit components, l (1) Water content reference values whilst the graph on the following page l (2) Water content reference values shows relative static pressures.
SoUND DAtA Sound power Total sound levels Octave band [Hz] Aermec determines sound power values in Pressure. 1000 2000 4000 8000 Pow. agreement with the 9614 Standard, in com- dB(A) dB(A) Sound power for centre of band [dB] frequency dB(A)
AND INStALLAtIoN StANDArDS INStALLer gning and constructing the unit: Must be installed by a qualified and suitably AERMEC ANLs are constructed according to the re- ProteCtIoN rAtINg trained technician, in compliance with the cognised technical standards and safety regulations. IP 24...
SeLeCtIoN AND PLACe oF IN- 19.2.2. eXeMPoL oF MoVIMeNtAtIoN StALLAtIoN Before beginning installation consent with client and pay attention to the following recommendations: The support surface must be capable of sup- porting the unit weight; The safety differences between the unit and ther appliances or structures must be scrupu- lously respected so that the inlet and outlet AIR from the fans is free to circulate;...
HYDrAULIC CIrCUItS oF PrINCIPLe 20.1. HYDrAULIC CIrCUIT FOr InTErnAL AnD ExTErnAL AnL "H" (standard) HYDrAULIC HYDrAULIC CoMPoNeNtS CoMPoNeNtS AtteNtIoN SUggeSteD eXterNAL UNIt The choice and the installation of components external to the ANL °|H èup to the installer, who must operate according to the rules of good technical design and in compliance with the regulations in force in the country of destination.
20.2. CIrCUITO IDrAULICO InTErnO ED ESTErnO AD AnL “HP" HYDrAULIC HYDrAULIC CoMPoNeNtS CoMPoNeNtS AtteNtIoN SUggeSteD eXterNAL UNIt The choice and the installation of components external to the ANL °|H èup to the installer, who must operate according to the rules of good technical design and in compliance with the regulations in force in the country of destination.
20.3. HYDrAULIC CIrCUIT FOr InTErnAL AnD ExTErnAL AnL "HA" AtteNtIoN HYDrAULIC HYDrAULIC CoMPoNeNtS The choice and the installation of CoMPoNeNtS SUggeSteD eXterNAL UNIt components external to the anl°a|Q /anlHa|HQ up to the installer, who must operate accor- ding to the rules of good technical design and in compliance with the regulations in force in the country of destination.
DIMeNSIoNS 21.1. AnL 100 - 150 H|HP|HA VErSIOn 1450 mm 57.1 in 1750 mm 1800 mm 68.9 in 70.9 in 750 mm 29.5 in ANtIVIBrAtIoN PoSItIoNINg AND DIStrIBUtIoN oF PerCeNtAge oN SUPPortINg PoINtS 80 mm 1590 mm 80 mm 3.1 in 62.6 in 3 in Ø...
The minimum technical spaces have been aermec.com) respected - The anti-freeze control Check the correct functioning of the flow/ That the power cables are generally of appro- priate section, to withstand the overall drive pressure switch if installed. Closing the cut-off The anti-freeze control managed by the electronic power consumption. (see section Electrical...
FUNCtIoNINg FeAtUreS 26.1. Set PoINt IN CooLINg MoDe Whenever alarms do not occur, the compressor AtteNtIoN starts. 11 This anti-freeze set tempera- (Factory set) = 7°C, ∆t = 5°C. ture can only be varied by an 26.5. AnTI-FrEEZE ALArM authorised after-sales centre 26.2.
MAINteNANCe all cleaning is prohibited until the unit has been because it is a pollutant. It must be collected and, if AtteNtIoN We recommend that you include a disconnected from the electric power supply mains. possible, reused. booklet machine (not supplied, but Make sure there is no voltage present before operat- at the expense user), which allows to 27.4.
To enter and edit the menu INStALLeD following at the value 3 the same procedure for the user menu. installer password menu: 030 AtteNtIoN For more information, refer to USer manual supplied with the chiller and is also available on www.aermec.com 1205. 6755517_02...
Page 36
Papier recycled papier AERMEC S.p.A. 37040 Bevilacqua (Vr) italy–Via roma, 996 The technical data in the following Tel. (+39) 0442 633111 documentation are not binding. Aermec Telefax 0442 93730–(+39) 0442 93566 reserves the right to make all the www.aermec.com - info@aermec.com modifications considered necessary for improving the product at any time.