Dear customer, Thank you for choosing an AERMEC product. It is the fruit of many years of experience and special design studies and has been made of the highest grade materials and with cutting edge technology. The quality level is being constantly monitored, so AERMEC products are synonymous with Safety, Quality and Reliability.
6.2. HEATING MODE ....................11 PRESSURE DROP ................12 HYDRAULIC CONNECTION ...............27 7.1. SYSTEM SIDE EXCHANGER + PIPING PRESSURE DROP ........12 22.2. ANK 030-045-050 H ..................27 22.1. ANK 030-045-050 HA ..................27 USEFUL STATIC PRESSURES .............12 ELECTRICAL CONNECTIONS.............28 GLYCOL SOLUTIONS .................13 23.1. ELECTRICAL DATA ................28 MINIMUM/MAXIMUM OF SYSTEM WATER CONTENT ....14...
DESCRIPTION AND CHOICE OF UNIT WARNING The heat pumps for OUTDOOR condensed in the air with R410A Series ANK have been designed Before the use (or after a prolonged period of sus- and manufactured to satisfy heating and cooling pension) of units destined to function with low needs in medium to small commercial or residential air temperature and also the heat pumps, it is of buildings.
PRINCIPLE OF OPERATION DIAGRAMS COOLING valvola inversione accumulo compressore liquido O DELIVERY SYSTEM SIDE pompa O ETURN SYSTEM SIDE CP Compressor HPT High pressure transducer HPS High pressure switch LPT Low pressure switch VIC 4-way cycle reverse valve CN Coil CV One-way valves CO Orifice F Dehydrator filter...
3.1. COOLING CIRCUIT 3.4. HYDRAULIC CIRCUIT (CONFIGURABLE VERSION) Compressor Flowswitch High efficient scroll on anti-vibration mounts, activated by a 2-pole electric Positioned above evaporator, it has the task of controlling that there is water motor with internal heat protection. They are supplied, as standard, with an circulation.
3.7. ELECTRIC COMPONENTS Electric Control Board Contains the power section and the management of Regolazione elettronica controls and safety devices. It is in compliance with MODU CONTROL the IEC 60204-1 Standard and the Directives regard- ing electromagnetic compatibility EMC 89/336/CEE Temperature control of the output water with proportional-integral and 92/31/CEE.
ACCESSORIES AERNET DCPX The device allows the control, the management and the remote monitoring of a Device for condensation temperature control, with continuous speed modulation Chiller with a PC, smartphone or tablet using Cloud connection. AERNET works as of fans by using a pressure transducer. Master while every unit connected is configured as Slave (max.
44,6-42,8°F / 7-6°C Empty weight "HP" ∆t 10,01°F / 5°C DIMENSIONS HA VERSION Height [3] The reported data can be amended any time Aermec Width considers it necessary. Depth [4] Sound power Empty weight "HA" Aermec determines sound power values in agreement with the 9614-2 Standard, in compliance with that requested by Eurovent certification.
In the windy zones, for a correct operation of the DCPX the installation of the windbreak recommen- ds him. 6.1. COOLING MODE 6.2. HEATING MODE Operation limit valid to all ANK model. Operation limit valid only to ANK 030-045. °C °F °C °F Standard functioning STANDARD STANDARD...
MINIMUM/MAXIMUM OF SYSTEM WATER CONTENT Hydraulic height ≥ 12.25 Calibration of expansion vessel We recommend using an equal volume of water in Recommended values of water content. 10 l / kW. Recommended values of water content. When operating in heat pump during defrosting, this value can contain acceptable values to reduce the Corrective Recommended...
An accidental release of refrigerant may cause risk of suffocation currently in force. Assess the procedures Aermec requires and due to a lack of oxygen: install the machine in a well ventilated...
Page 17
Install the unit at a distance enough from the exhaust wells, to ensure The machine and the pipes have very hot and very cold surfaces that that the possible loss of gas may reach and pollute the aquifer lead to risk of burns Keep all lubricants in properly marked containers do not keep Before opening a machine panel, ascertain whether it is or not firmly flammable liquids near the plant...
SELECTION AND PLACE OF INSTALLATION Before beginning installation consent with client and 14.1. MINIMUM TECHNICAL pay attention to the following recommendations: The support surface must be capable of sup- porting the unit weight; The safety differences between the unit and ther appliances or structures must be scrupu- lously respected so that the inlet and outlet AIR from the fans is free to circulate;...
ATTENTION: The use of anti-vibration supports MUST be combined with the installation in the unit water piping of exible couplings. The anti- vibration supports must be xed to the unit BEFORE it is earthed. AERMEC is not responsible for the choice of capacity of the anti-vibration supports.
flow fittings have not been reversed). The water circulation pump must may occur with these anti-freeze solutions in contact with oxygen. aermec.com at minimum temperature provided for a given installation. Take the preferably be installed upstream so that the evaporator/condenser is However, always refer to the glycol supplier documentation to check its subject to a positive pressure.
HYDRAULIC CIRCUITS OF PRINCIPLE 17.1. HYDRAULIC CIRCUIT FOR INTERNAL AND EXTERNAL ANK “H” (standard) HYDRAULIC HYDRAULIC COMPONENTS ATTENTION COMPONENTS ANK SUGGESTED EXTERNAL UNIT The choice and the installation of components external to the ANK H up to the installer, who must ope- rate according to the rules of good technical design and in compliance with the regulations in force in the...
17.2. HYDRAULIC CIRCUIT FOR INTERNAL AND EXTERNAL ANK “HP” HYDRAULIC COMPONENTS HYDRAULIC COMPONENTS ANK HP SUGGESTED EXTERNAL UNIT ATTENTION The choice and the installation of components external to the ANK H up to the installer, who must ope- rate according to the rules of good technical design and in compliance with the regulations in force in the country of destination.
17.3. HYDRAULIC CIRCUIT FOR INTERNAL AND EXTERNAL ANK “HA” HYDRAULIC COMPONENTS HYDRAULIC COMPONENTS ANK HA SUGGESTED EXTERNAL UNIT ATTENTION The choice and the installation of components external to the ANK H up to the installer, who must ope- rate according to the rules of good technical design and in compliance with the regulations in force in the country of destination.
SYSTEM EXAMPLE (CHILLER + DHW) zone 1 zona 1 zona 2 zone 2 zona 3 zone 3 1 - Unità ANK HA Unit; 2 - DIVERTER 3-way valve; 3 - Expansion vessel; 4 - Safety valve; 5 - Area mixer valve (*); 6 - Zone pump (*);...
DIMENSION (mm/in) ANK [H-HP] 030-045-050 ANK [HA] 030-045-050 1281 mm 1281 mm 50 in 50 in 1450 mm 57 in 1000 mm 450 mm 450 mm 18 in 39 in 18 in ANTIVIBRATION POSITIONING (mm/in) ANK [H-HP] 030-045-050 ANK [HA] 030-045-050 410 mm 16 in 360 mm...
HYDRAULIC CONNECTION 22.2. ANK 030-045-050 H Ø 1”¼ Ø 1”¼ Reducer for connection 235 mm STANDARD SUPPLIED 110 mm 9 in 4 in 53.6 mm 2.1 in 22.1. ANK 030-045-050 HA Ø 1”¼ Ø 1”¼ 205 mm 110 mm 8 in...
The absorption of the unit and the physical location, and the ambient ineffective appliance earth connection. temperature. For units with three-phase power supply, check the correct connection of the phases. 23.1. ELECTRICAL DATA ELECTRICAL DATA MODELS M.U. ANK 030 ANK 045 ANK 050 42.30 42.30 42.30 Peak current (LRA) HP-HA 43.30 43.30...
COMMISSIONING - WARNINGS COMMISSIONING Please note that, on request by the Aermec customer or the legitimate owner of the machine, the units in this series can be started up by Once all the aforementioned checks have been carried out, the unit...
MAINTENANCE MAINTENANCE ATTENTION place before restarting the unit; Any cleaning, inspection, control, routine and extraordinary mainte- It is not permitted to walk or place other bodies on the machine; nance must be performed by experienced, authorised personnel and Fans, motors and belt drives may be in motion, always wait for them quali ed to perform the above tasks.
Page 31
Always and only use original spare parts purchased directly from Aer- if these devices intervene, the refrigerant gas is released at high mec or from official dealers. Contact Aermec should it be necessary temperature and speed; The machine and the pipes have very hot or very cold surfaces that to move the unit one year after its positioning on-site or it must be lead to risk of burns by contact;...
Page 32
The high/low pressure switch, where present must be tested with the With machine off, access its cooling circuit; Connect the necessary instruments, machine “closed”, reading the high pressure circuit pressure on the machine • Pressure gauges connected through appropriate extensions to the control panel.
MAINTENANCE - LIST OF THE RECOMMENDED PERIODIC INTERVENTIONS MAINTENANCE - LIST OF THE RECOMMENDED PERIODIC INTERVENTIONS RECOMMENDED PERIODIC MAINTENANCE INTERVENTIONS FREQUENCY DESCRIPTION functioning hours months months months months GENERAL INTERVENTIONS Check of any refrigerant leaks (this must be done respecting the deadlines recommend- •...
Page 34
MAINTENANCE - LIST OF THE RECOMMENDED PERIODIC INTERVENTIONS RECOMMENDED PERIODIC MAINTENANCE INTERVENTIONS TO UNITS WITH CENTRIFUGAL COMPRESSORS FREQUENCY DESCRIPTION 6 months 12 months other GENERAL CHECKS Check that the compressor is not damaged • Check that there are no excessive vibrations induced by other operating components •...
Page 36
Via Roma, 996 37040 Bevilacqua (VR) - Italia Tel. + 39 0442 633111 Fax +39 0442 93577 marketing@aermec.com www.aermec.com Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.