Kenwood RD-C707-S Service Manual page 25

Table of Contents

Advertisement

AJ
160)
SEGMENT
SEG19
32
2.8V
OUTPUT
P20
CIRCUIT
SEG20
31
2.8V
M
SEG21
30
1.4V
16)
P22
SEG22
29
2.8V
P23
SEG23
28
2.8V
P24
SEGMENT/
SEG24
27
4.1V
DIGIT
P25
SELECT/
SEG25
26
4.1V
P26
OUTPUT
SEG26
25
2.8V
CIRCUIT
P27
24
0V
VP
SCAN
SEG27
23
4.2V
PULSE
P28
SEG28
22
2.9V
DIGIT
P29
OUTPUT
SEG29
21
4.3V
P30
CIRCUIT
SEG30
20
1.5V
SEG31
19
5.8V
P32
SEG32
18
8.4V
P33
SEG33
17
6.9V
P34
P35
3.9V
27
P
2
+VP
R746
2.7K 1/2W
+3.3V
RP748
10K
11.4V
RP749
4.7
11.7V
3.9V
2.5V
34
33
32
31
+3.3V
RD03
RD04
RD05
3.3K
5.6K
10K
USB
IPOD
INPUT
LAY/PAUSE
PLAY/PAUSE
SELECTOR
SW703
SW704
SW705
VOL UP
SW710
AK
ILLU LED
0V
0V
CNP704
BI704
Q719
2
2
0V
R723
1
1
10
P21
CNP702A
39
8
MD SEARCH
48
7
MD ST
40
6
MD RESET
MAIN-
CNP702B
47
5
MD PCNTO
45
4
MD DATA
2/4
44
3
K DATA
43
2
MD DSCK
N-7
42
1
MD DTSB
P31
(E,X)TYPE
ONLY
CNP701A
25
30
RDS VOLT CTRL
24
29
RDS DATA
19
28
RDS CLK
27
27
S MUTE
+VF
26
+VF
37
25
HP MUTE
38
24
FUNC CTRL
30
23
IPOD RX
29
22
IPOD TX
26
21
IPOD DET
22
20
REC LVL
21
19
DC RELAY
18
D CTRL
1
17
AMP STANDBY
2
16
AMP MUTE
6
15
IPOD FUNC
7
14
USB FUNC
100
13
REC MUTE
97
12
SYS PROTECT
88
11
CE
87
10
DI
86
9
CLK
85
8
DO
7
SW 3.3
6
-VF
5
+VP
4
69
HP SW
+9.1V
3
ILLU +9V
DC12V
2
DC 12V
1
GND
RD-CLK7 ONLY
u-COM REFRESH
BI702
CNP105
CNP106
FRESH BUSY
1
FRESH BUSY
1
1
2
NC
FRESH SCL
3
FRESH SCL
2
2
FRESH RXD
4
FRESH RXD
3
3
FRESH TX
5
FRESH TX
4
4
RESET
6
RESET
5
5
CNVSS
7
CNVSS
6
6
UNSW 3.3V
8
UNSW 3.3V
7
7
VSS
9
VSS
8
8
SPK OUT
BI901
L+
5
SO901
STOP
4
L
L-
3
SW706
R-
2
R
R+
1
MAIN-
CNP901
2/4
T-3
RD-C707 (4/4)
DISAPLY (3/3), TACT SWITCH (2/2), ILLU LED (1/1), SPK OUT/μ-COM REFRESH (1/1)
AL
MAIN-
CNP701B
2/4
P-7
CAUTION: For continued safety, replace safety critical components
only with manufacturer's recommended parts (refer to parts list).
indicates safety critical components. For continued protection
against risk of fi re, replace only with same type and rating fuse(s).
To reduce the risk of electric shock, leakage-current or resistance
measurements shall be carried out (exposed parts are acceptably
insulated from the supply circuit) before the appliance is returned to
the customer.
The DC voltage is an actual reading measured with a high imped-
ance type voltmeter with no signal input. The measurement value
may vary depending on the measuring instruments used or on the
product.
AM
AN
C-707I
1
2
3
4
5
6
7
25

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rd-c707-wLs-c707-sLs-c707-w

Table of Contents