918 Roll Groover
Table III. Copper Roll Groove Specifications
NOTE: All Dimensions are in Inches.
Tubing Outside
Nom.
Diameter O.D.
Size
Inches
Basic
2
2.125
2
1
/
2.625
2
3
3.125
4
4.125
5
5.125
6
6.125
(1) Copper Tubing to the following standards: ASTM B88 & ASTM B306.
(2) Nominal Groove Depth is provided as a reference dimension. Do not use groove depth to determine groove acceptability.
(3) "DWV" – ASTM B306 Drain Waste & Vent Tubing wall thickness.
22
A
Gasket
Seal A
Tolerance
±0.03
±0.002
0.610
±0.002
0.610
±0.002
0.610
±0.002
0.610
±0.002
0.610
±0.002
0.610
B
C
Groove
Groove
Width
Dia.
+.03 / –.000 +.000 / –.020
0.300
2.029
0.300
2.525
0.300
3.025
0.300
4.019
0.300
5.019
0.300
5.999
D
T
Nominal
Min.
Groove
Allow.
Depth
(2)
Wall Thick.
(3)
0.048
0.064
0.050
0.065
0.050
0.045
0.053
0.058
0.053
0.072
0.063
0.083
999-998-946.10_REV. C
Max.
Allow.
Flare Dia.
2.220
2.720
3.220
4.220
5.220
6.220