Questions and answers

Summary of Contents for FAAC XKPR

  • Page 1 XKPR...
  • Page 2: Table Of Contents

    Dati tecnici ........7 2. XKPR ......... 7 3.
  • Page 3 Istruzioni originali 1 Ø 3.5 mm Guarnizione di tenuta IP Ø 15 mm  2 BUS SPINet: Morsetti • Buzzer • XKPR 532192 - Rev.C...
  • Page 4 Istruzioni originali 3 BUS SPINET Door Controller Cavo SPINet MAX 30 mt - Cavo SPINET -cod. S-CAVO-BUS - 2 coppie twistate da 0.5 mm 2 con schermo. XKPR 532192 - Rev.C...
  • Page 5 Istruzioni originali  4 - Selezione Lettore A o B • 5 Guarnizione di tenuta IP XKPR 532192 - Rev.C...
  • Page 6: Installazione

    1. Predisporre i cavi di collegamento e fissare la base. Rispettare le indicazioni di 1 . 2. Collegare XKPR ai morsetti SPINet della scheda Door Controller. Rispettare le indicazioni di 2 e 3. - Scoprire dalla guaina almeno 1 cm di conduttore.
  • Page 7: Dati Tecnici

    Il lettore XKPR fa parte della gamma FAAC di dispositivi controllo accessi. XKPR consente la lettura di un tag o la digitazione di codici numerici riservati a ogni utente. Ogni codice utente deve essere memorizzato sul Door Controller per essere validato.
  • Page 8: Collegamento Alla Scheda Con Spinet

    Media di Accesso in Keydom. il Led rosso. MANUTENZIONE Pulire solo le superfici esterne con un panno morbido. Non utilizzare detergenti né oli. Non eseguire alcuna modifica ai componenti originali. Per le sostituzioni utilizzare esclusivamente ricambi originali FAAC. XKPR 532192 - Rev.C...
  • Page 9 Technical data ....... 14 2. XKPR ........14 3.
  • Page 10 Translation of the original instructions 1 Ø 3.5 mm IP sealing gasket Ø 15 mm  7 SPINet BUS: Terminals • Buzzer • XKPR 532192 - Rev.C...
  • Page 11 Translation of the original instructions 2 SPINET BUS Door Controller SPINet cable MAX 30 m - SPINET cable -cod. S-BUS CABLE - 2 shielded twisted two pair cable 0.5 mm 2 . XKPR 532192 - Rev.C...
  • Page 12 Translation of the original instructions 3 - Reader A or B selection •  4 IP sealing gasket XKPR 532192 - Rev.C...
  • Page 13: Installation

    (1 ) and in the body (5). 1. Prepare the connecting cables and install the base. Follow the instructions given in  1 . 2. Connect the XKPR to the SPINet terminals of the Door Controller board. Follow the instructions given in  2 and 3.
  • Page 14: Technical Data

    The XKPR reader is included in the FAAC range of access control devices. The XKPR allows a tag to be read or numeric codes to be entered that are restricted to each user. In order to be valid, each user code must be stored on the Door Controller.
  • Page 15: Connecting To The Board With Spinet

    LED lights up. MAINTENANCE Clean the outer surfaces only with a soft cloth Do not use detergents or oils. Do not make any modifications to the original components. Only use original FAAC spare parts. XKPR 532192 - Rev.C...
  • Page 16 FAAC S.p.A. Soc. Unipersonale Via Calari, 10 - 40069 Zola Predosa BOLOGNA - ITALY Tel. +39 051 61724 - Fax +39 051 758518 www.faac.it - www.faacgroup.com XKPR 532192 - Rev.C...