Selection Of Location For Installation - Mitsubishi Heavy Industries SRK20HD Technical Manual

Wall mounted type room air-conditioner
Table of Contents

Advertisement

5.1 Selection of location for installation

(1) Indoor unit
(a)
Where there is no obstructions to the air flow and where the cooled
air can be evenly distributed.
(b) A solid place where the unit or the wall will not vibrate.
(c)
A place where there will be enough space for servicing. (Where
space mentioned below can be secured)
(d) Where wiring and the piping work will be easy to conduct.
(e)
The place where receiving part is not exposed to the direct rays of
the sun or the strong rays of the street lighting.
(2) Outdoor unit
(a)
A place where good air circulation can be obtained and where rain, snow or sunshine will not directly strike the unit.
(b)
A place where discharged hot air or unit's operating sound will not be a nuisance to the neighborhood.
(c)
A place where servicing space can be secured.
(d)
A place where vibration will not be enlarged.
100
(e)
In heating operation, snow deposit on the heat-exchanger of outdoor unit must be
prevented for keeping the normal performance capacity.
(i)
Snow-hood on outdoor unit as in drawing, will reduce the frequency of
defrost operation.
When installing the snow hood, take care so that the air outlet of the snow
hood will not face directly into the most windy direction.
(ii) Design the base higher than possible snow deposit.
(3) Limitations for one way piping length and vertical
height difference.
Model
Item
One way piping length (R)
Outdoor
Vertical height
unit is lower
difference (h)
Outdoor unit
is higher
Unit : mm
Air inlet
No obstacles
(Service space
for electrical
parts)
Air
Outlet
SRK20HD
15 m
5 m
5 m
-
6.5 cm
Left
side
5 cm
Notes (1) Blowing out port and suction port on the back side of the unit can be
installed at a distance of 10cm from walls.
(
In case the barrier is 1.2m or above in height, or is overhead, the
sufficient space between the unit and wall shall be secured.
(2) When the unit is installed, the space of the following dimension and
above shall be secured.
18
-
: http://splitoff.ru/tehn-doc.html
Right
side
10 cm
1.5 cm
Snow hood
Height:
Must be over
the possible
snow deposit
height
h
r
)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Src20hd