Page 1
Hydmaster 40 OPERATING AND MAINTENANCE INSTRUCTIONS LIFA Hydmaster 40 Electric ventilation cleaning machine for demanding use, powered by hydraulic motor. Hydmaster 40 (without camera) These instructions should always be available for the personnel who use the machine. Please read these instructions before operating the machine. Observing and following of...
Hydmaster 40 INDEX Hydmaster 40 ....................1 (without camera) GENERAL DIRECTIONS......................3 LIFA HYDMASTER 40......................4 TECHNICAL INFORMATION....................5 CONSTRUCTION AND CONTROL..................6 SAFETY PRECAUTIONS.....................7 OPERATING PRINCIPLES....................9 THE USE OF THE MACHINE.....................10 MAINTENANCE........................13 SPARE PARTS........................14 PROBLEM SITUATIONS....................14 WARRANTY........................15 RECYCLING........................15 DECLARATION OF CONFORMITY...................16...
European Union. Viewpoints and regulations on the safe use of machines change over time. If the person using the Lifa’s equipment notices any reasons or possibilities for improving work safety, Oy Lifa Air Ltd. would be more than grateful to receive such information.
Hydmaster 40 is designed for ducts that have a diameter from D 315 mm to D 1200 mm (12.4 – 47.25 inches) The rotating speed of the brush has a stepless speed variation from 340 to 650 rpm.
Hydmaster 40 TECHNICAL INFORMATION The following information refers to the basic model of Hydmaster 40. Operating power: Electricity Operating voltage: 230 V AC (120 V AC) Frequency: 50 - 60 Hz Motor: Hydraulic motor 1.1 kW; 4.7 A Fuse / Breaker...
Hydmaster 40 CONSTRUCTION AND CONTROL 1. Main switch 2. Variable speed AC Motor Drive 3. Safety switch for motor 4. Pneumatic pedal- The change of the rotating and operating direction 5. Control of the rotating speed 6. Oil pressure meter 7.
Hydmaster 40 has a strong rotating force. Clothes or hairs can easily get caught in the brush and cause damage or accidents. The brush has to be placed always in the ventilation duct before starting the machine.
Page 8
The earth connection shall always be connected! Ensure that the power supply is earth connected! Only an authorized electrician can do the electrical connections! 8. Noise level The noise level of Hydmaster 40 is low and it is not dependent of the operating environment.
OPERATING PRINCIPLES 1. Permissible use Hydmaster 40 is an electrical cleaning machine for ventilation ducts. It cleans the inner surfaces of the ducts with mechanically operated brush. The machine is meant for ducts that have a diameter from 315 mm to 1200 mm (12.4 – 47.2 inches) as well as rectangular and circular ducts.
Hydmaster 40 THE USE OF THE MACHINE Before beginning the work check the channel network with Lifa DuctTruck (accessory). There may be air volume controllers, noise silencers, fire dampers etc. that can be damaged during the work. In large rectangular ducts, there might be supporter poles inside the duct. Use extra ...
Page 11
Hydmaster 40 ACCESSORIES SOFT BRUSH WITH NYLON CENTER AND DISK 6420281010507 200 / 400 mm 6420281010514 300 / 500 mm 6420281012624 400 / 600 mm 6420281010736 500 / 700 mm 6420281013027 600 / 800 mm 6420281010743 700 / 900 mm...
Page 12
Hydmaster 40 GREASE AND HEAVY DUTY BRUSH, CHOPPER (WITH SPECIAL ADAPTER) 6420281020216 Grease Duct chopper, Large (800 mm) adjustable for ducts 500-1100 mm 6420281020209 Grease Duct chopper, Small (350 mm) adjustable for ducts 250-500 mm 6420281013010 Y-Gear -for rectangular ducts >200mm in...
Hydmaster 40 MAINTENANCE When the machine is in daily professional use it should be delivered to its first regular maintenance to the manufacturer or to repair shop that has been authorized by the manufacturer after six months from the first commissioning date (approximately 100 hours).
After that the oil change has to be done every year. Only Shell TELLUS T 32-hydraulic oil can be used in the Hydmaster 40 (Technical information). Make sure that there is always the required amount of oil in the machine unit. The minimum is in the level 50% of the oil level meter seen, the maximum in the oil level meter of 80%.
A written reclamation form has to be filled out and sent with descriptive photos The appliance shall be delivered to the authorized Lifa Air representative from whom the buyer has bought the machine from OR when agreed mutually in writing beforehand to the...
+358 9 3948 58 Model: Hydmaster 40 Oy Lifa Air Ltd, hereby states, with sole responsibility, that the machine models covered by this announcement comply with the requirements of the following directives: The above equipment complies with the following directives:...