Daikin FTXM09VVJU Service Manual page 10

Hide thumbs Also See for FTXM09VVJU:
Table of Contents

Advertisement

Electrical Box
Step
8
Remove the screw and
detach the earth/ground
wire.
9
Pull out the indoor heat
exchanger thermistor.
10 Remove the screw of
the electrical box.
11 Pull the electrical box to
the front and remove it.
12
Remove the screw and
unfasten the hook to
detach the conduit
mounting plate.
13
Loosen the nut lock and
remove the conduit
together with the
connecting wire.
8
Procedure
Indoor heat exchanger thermistor
Back view
Nut lock
Hook
Earth/ground wire
(R26157)
Electrical box
(R26158)
Bottom frame
Hook
Fan motor wire
Conduit mounting plate
Conduit
(R26159)
Si042153E
Points
 Screw size: M4 × 12 (with
washer)
 Be careful not to lose the clip
of the thermistor.
Clip
 The position of the indoor
heat exchanger thermistor
varies depending on the
model.
 When reassembling, make
sure that the 2 hooks are
securely fastened to the
bottom frame.
 When reassembling, be
careful not to get the fan
motor wire caught between
the electrical box and the
bottom frame.
Removal Procedure