Chapter 3 Operation Method - Pro XK3190-DS3 Operation Command

Weighing display controller
Table of Contents

Advertisement

be ASCII code letter for sending, for example, Xor checking four higher bit is B. With 37h added, it is
42h, i.e. letter B in ASCII code for sending out.
3. Command list sent by host computer (set address of the indicator as 01):
Content of Command Host computer sends out commands (hexadecimal)
Category
Command A Hand shaking
Command B Reading gross weight 02 41 42 30 33 03
Command C Reading tare
Command D Reading net weight
4. Indicator communication parameter setting:
(1). Communication parameters
Communication parameters are made up of three groups of parameters, i.e. communication address, baud
rate and communication method.
(2) Steps for setting communication parameters:
Step
Operation
1
Press [Parameter
setting]
2
Press [9][8]
Press [Input]
3
Press [1]
Press [Input]
4
Press [1]
Press [Input]
5
Press [0]
Press [Input]
6
Note 2: In the old D2+ continuous communication format, data is output in form of ASC code with 8
bits in every frame (including the decimal point). Lower bits of the data are sent at first and then
the higher ones. The frames are divided by "=". Data being sent is the net weight (i.e. the value
displayed on indicator), for example, when the value 70.15 is displayed, the indicator
continuously sends out 51.0700=51.0700=51.0700.......
In the new D2+ (300 tons) continuous communication format, data is output in form of
ASC code with 9 bits in every frame (including the decimal point). Lower bits of the data are
sent at first and then the higher ones. The frames are divided by "=". Data being sent is the net
weight (i.e. the value displayed on indicator), for example, when the value 70.15 is displayed,
the indicator continuously sends out 51.07000=51.07000=51.07000......
X K 3 1 9 0 –DS3
02 41 41 30 30 03
02 41 43 30 32 03
02 41 44 30 35 03
Displayed content
In the weighing and
displaying state
[ P
00 ]
Input the setting password "98"
[ P
98 ]
[ Ad r ** ]
Address ( 01~26 )
[ Ad r 01]
E.g.: 1
[ b t
* ]
Baud rates of serial communication (0~4)
means following baud rates respectively:
[ b t
1]
600, 1200, 2400, 4800 and 9600 baud rates.
E.g.:1
[ t F
* ]
Way of serial communication:
[ t F
0 ]
format, 8 bits every frame
format, 9 bits every frame
(See Note 2)
E.g. 0
Weighing state
Communication parameter setting is
completed
Chapter 3
Operation Method
(7)
Note
0—Continuous send mode, no reception
1—Appointed answering mode
2—Old D2+ continuous communication
3—New D2+ continuous communication

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents