Reassembly Instructions
Power Board PCBA and / or & Pump Assy replacement.
In case of PCBA and / or pump replacement, follow as per below instruction to ensure matching of both
hardware.
a) For PCBA replacement:
- To cut the jumper wires (J1, J2) on PCBA based on the pump label as in Table 1 below.
b) For pump replacement:
Pump spoilt?
YES
Change Pump
YES
Same Pump
available?
YES
Replace Pump
accordingly
Table 1
Jumper wires on PCBA
J2
Published by Philips Consumer Lifestyle
Document No. : CSW-07-081-18111
Change PCBA
YES
Cut Jumper wire per
table 1
Label on Pump
J1
Pump label
23 |
P a g e
Jumper wire to cut on
PCBA
1
J1 (Pump -1)
2
J2 (Pump-2)
For internal use only