Reassembly Instructions
Replacing ELECTROVALVE
To prevent damage to the ELECTROVALVE during service activity, the following to be observed during
disassembly & assembly.
Tool required: Torque wrench (set to 6Kgf)
CAUTION #1: The torque wrench engagement is allowed ONLY at the yellow box locations in
CAUTION #2: Ensure torque wrench jaw does not contact the solenoid body.
Published by Philips Consumer Lifestyle
Document No. : CSW-07-081-18111
below picture.
22 |