  • Page 1 LAKEPRO-1 WI-FI TOUCHSCREEN PROGRAMMABLE THERMOSTAT...
  • Page 2 1001 Park Centre Blvd Miami Gardens, Florida 305.471.7600 www.vtronix.com You can download a copy of this manual at https://vtronix.com/5-residential-thermostats...
  • Page 3: Table Of Contents

    Contents APPLICATION ..........................1 FEATURES ............................2 SPECIFICATIONS ......................... 3 INSTALLATION ..........................5 WIRING ............................13 POWERING UP THE THERMOSTAT ..................30 INSTALLER SETUP ........................33 OPERATION ........................... 44 PROGRAMMING A SCHEDULE ....................66 FCC Note ............................. 71 TROUBLESHOOTING ........................73...
  • Page 5: Application

    APPLICATION The Lakepro-1 Wi-Fi touchscreen programmable thermostat is an easy to use 7-Day programmable thermostat that provides universal system compatibility, precise comfort control and ease of programming. The Lakepro-1 provides temperature control for gas, oil, electric conventional systems and heat pumps for up to 3 heat stages and 2 cool stages.
  • Page 6: Features

    FEATURES Large, clear display with backlight shows room temperature, set temperature and · humidity. Menu-driven programming makes for easy setup. · Capacitance touchscreen interaction. · Optional connection to the Internet to monitor and control the heating/cooling system · remotely. Compressor protection. ·...
  • Page 7: Specifications

    SPECIFICATIONS Temperature Setting Range Heating: 40°F to 90°F (4°C to 32°C). Cooling: 50°F to 99°F (10°C to 37°C). Operating Ambient Temperature: 32°F to 122°F (0°C to 50°C). Shipping Temperature: 14°F to 140°F (-10°C to 60°C). Temperature Accuracy: ±2℉. Operating Relative Humidity (Non-condensing): 5% to 95%.
  • Page 8 Displays "Cool On" on the screen when Cool is activated. Heat Indication: Displays "Heat On" on the screen when Heat is activated. Auxiliary Heat Indication: Displays "Aux On" on the screen when Auxiliary Heat is activated. Emergency Heat Indication: (heat pump with backup heat only) Displays “Emer”...
  • Page 9: Installation

    INSTALLATION When Installing this Product... Read these instructions carefully. Failure to follow the instructions can damage the product or cause a hazardous condition. Check the ratings given in the instructions to make sure the product is suitable for your application. The installer must be a trained, experienced service technician.
  • Page 10 Dimensions: Lakepro-1 front and side dimensions: see Fig. 1. Lakepro-1 rear dimensions: see Fig. 2. Lakepro-1 wall plate dimensions: see Fig. 3. Fig. 1. Lakepro-1 front and side dimensions in inches. (mm).
  • Page 11 Fig. 2. Lakepro-1 rear dimensions in inches. (mm).
  • Page 12 Fig. 3. Lakepro-1 wall plate dimensions in inches. (mm).
  • Page 13 Fig.4. Selecting the thermostat location.
  • Page 14 Installing the Wall plate CAUTION Electrical hazard! Can cause electrical shock or equipment damage. Disconnect power before wiring. The thermostat should be mounted horizontally on the wall. If mounting on dry wall: Position and level the wall plate on the wall. Use a pencil to mark the inner mounting holes.
  • Page 15 Note: If you are mounting on a vertical 2x4 electrical box or on a 4x4 electrical box you will need to purchase an adapter ring.
  • Page 16 Fig.5. Mounting wall plate.
  • Page 17: Wiring

    WIRING All wiring must comply with local electrical codes and ordinances. See Table 1 and Fig.6 for terminal designation descriptions. Insert wires in the terminal block under the loosened screws. See Fig.7. Securely tighten each screw. Push excess wire back into the hole in the wall. Plug the hole with nonflammable insulation to prevent drafts from affecting the thermostat.
  • Page 18 Table 1. Terminal Designation Descriptions. Terminal Designation Description Power for cooling--connect to secondary side of cooling system 24v RC (see Note 1) transformer Power for heating--connect to secondary side of heating system 24v R (see Note 1) transformer Common wire from secondary side of 24V transformer Compressor contactor Fan relay Second stage cooling...
  • Page 19 NOTES: 1. When used in a single-transformer system, leave the metal jumper wire in place between RC and R. If used on a two-transformer system, remove the metal jumper wire between RC and R. If the thermostat is configured for a heat pump system, configure the changeover valve for energized on cool or heat in the Installer setup.
  • Page 20 Fig.7. Inserting wires in terminal block. IMPORTANT: Use 18 gauge thermostat wire.
  • Page 21 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. FACTORY INSTALLED JUMPER.DO NOT REMOVE. Fig. 8. Typical wiring for a conventional single-stage heat and cool system with a single Transformer (1H/1C conventional).
  • Page 22 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. REMOVE FACTORY INSTALLED JUMPER. Fig. 9. Typical wiring for a conventional single-stage heat and cool system with two transformers (1H/1C conventional).
  • Page 23 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. FACTORY INSTALLED JUMPER.DO NOT REMOVE. Fig. 10. Typical wiring for a heat-only system (1 H conventional).
  • Page 24 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. FACTORY INSTALLED JUMPER.DO NOT REMOVE Fig. 11. Typical wiring for a heat only system with the fan controlled by the thermostat (1H conventional).
  • Page 25 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. FACTORY INSTALLED JUMPER.DO NOT REMOVE Fig. 12. Typical wiring for a heat only power to open and power to close zone valve System.
  • Page 26 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. FACTORY INSTALLED JUMPER. DO NOT REMOVE Fig. 13. Typical wiring for a heat only system with a normally open zone valve.
  • Page 27 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. FACTORY INSTALLED JUMPER DO NOT REMOVE. Fig. 14. Typical wiring for a single stage cool only system (1C conventional).
  • Page 28 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. FACTORY INSTALLED JUMPER.DO NOT REMOVE Fig. 15. Typical wiring for a conventional multistage one or two-stage heating and one or two-stage cooling system with a single-transformer (2H/2C, 2H/1C or 1H/2C conventional).
  • Page 29 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. REMOVE FACTORY INSTALLED JUMPER. Fig. 16. Typical wiring for a conventional multistage one or two-stage heating and one or two-stage cooling system with two-transformers (2H/2C, 2H/1C or1H/2C).
  • Page 30 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. FACTORY INSTALLED JUMPER. DO NOT REMOVE "O/B" TERMINAL MUST BE SET TO ENERGIZE EITHER ON "O" (FACTORY DEFAULT) OR "B" IN THE INSTALLER SETUP. Fig. 17. Typical wiring for a single-stage heat pump with no auxiliary/backup heat (1H/1C heat pump).
  • Page 31 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. FACTORY INSTALLED JUMPER.DO NOT REMOVE. "O/B" TERMINAL MUST BE SET TO ENERGIZE AS EITHER AS "O" (FACTORY DEFAULT) OR "B" IN THE INSTALLER SETUP. Fig. 18. Typical wiring for a multistage heat pump with no auxiliary/backup heat (2H/2C heat pump).
  • Page 32 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. FACTORY INSTALLED JUMPER. DO NOT REMOVE THE L TERMINAL IS SHOWN MONITORING AN OPTIONAL ALARM CONTACT. IF THE CONTACT CLOSES, THE THERMOSTAT WILL DISPLAY “ES”, OVERRIDING THE ROOM TEMPERATURE DISPLAY. "O/B"...
  • Page 33 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. FACTORY INSTALLED JUMPER. DO NOT REMOVE. THE L TERMINAL IS SHOWN MONITORING AN OPTIONAL ALARM CONTACT. IF CONTACT CLOSES, THERMOSTAT WILL DISPLAY “ES”, OVERRIDING THE ROOM TEMPERATURE DISPLAY. "O/B" TERMINAL MUST BE SET TO ENERGIZE AS EITHER "O" (FACTORY DEFAULT) OR "B" IN THE INSTALLER SETUP.
  • Page 34: Powering Up The Thermostat

    POWERING UP THE THERMOSTAT Wiring the 24VAC Common (“C” wire) Single-Transformer System: · Connect the common side of the transformer to the C screw terminal of the thermostat wall plate. Leave the metal jumper wire in place between RC and R. Two-Transformer System: ·...
  • Page 35 ALIGN PINS ON BACK OF THERMOSTAT WITH TERMINAL STRIP Fig.21. Mount thermostat to wall plate after aligning pins.
  • Page 36 Programming the thermostat Follow these steps to enter the: Installer Setup. These are parameters that should be selected by the installer at the time of the initial installation regarding the specific application and system type being controlled. b) User Setup. These are parameters that can be selected by the user regarding personal preferences which can be changed at any time after the initial installation.
  • Page 37: Installer Setup

    INSTALLER SETUP Follow these steps to enter the Installer Setup: See Fig. 22-1. Press and release the Key until the System mode blinks, then press and hold the key for approximately 5 seconds until the screen changes. The unit submenu number will display at the bottom right corner. See Fig. 22-2 (showing submenu 0150).
  • Page 38 2. Press key to select the submenu, and press the key to enter the submenu. Under submenu use to change the settings. See Fig.22-3. Fig.22-3. Press key to exit and confirm the changes, or press to exit without saving changes. Note: See Table 2 for the Installer Submenu Numbers and Settings.
  • Page 39 Table 2.Installer Setup Menu. Factory Defaults in Bold Submenu Name Settings Notes Number 0140 version See Firmware version (display only) Date and 0150 Set calendar date and time time If this setting is changed, user programmed non-programmable Schedule 0160 schedule will be erased Options 1-7 day programmable replaced...
  • Page 40 Submenu Name Settings Notes Number 1-1heat/1cool conventional 2-single-stage heat pump (no auxiliary heat) 3-Heat only conventional (no fan) 4-heat only conventional (with fan) 5-heat only (power to open and close zone valves or normally- open zone valves) System selection System 6-cool only conventional automatically modifies...
  • Page 41 in your system to ensure the heat pump and gas or oil system do not run at the same time. This thermostat will not manage that operation and cannot be used without an external fossil fuel kit. If you do not know if you have a fossil fuel kit, please contact a heating and/or cooling contractor to help you identify if you have one or not.
  • Page 42 Submenu Name Settings Notes Number Only shown 0-gas or oil furnace- equipment controls fan in conventional system heating Fan Control 0180 selected. If heat pump is 1-electric furnace- thermostat controls fan in in Heating selected, fan defaults to heating thermostat control. Changeover Valve O/B Terminal...
  • Page 43 Submenu Name Settings Notes Number 0-show temperature only Display in 0280 show main menu standby backlight off during standby Backlight 0– 0290 selection 1–backlight always on This refers to changing 0-manual changeover 0300 Changeover from Heat to Cool mode 1-auto changeover and vice versa 3°F (2°C) 2°F (1.5°C);...
  • Page 44 Submenu Name Settings Notes Number stage 0330 1 F, , 3 F (0.5C, , 1.5C) hysteresis stage 0340 1 F, , 3 F (0.5C, , 1.5C) hysteresis stage 0350 1 F, , 3 F (0.5C, , 1.5C) hysteresis furnace filter reminder off Furnace Filter 1-10 run time days 2-30 run time days...
  • Page 45 Submenu Name Settings Notes Number Conventional Recovery (system starts recovery at programmed time) Adaptive Shown only if 0160 is set 0530 Intelligent 1-Adaptive Intelligent Recovery control is activated to programmable Recovery (system starts early so set point is reached by start of program period).
  • Page 46 Submenu Name Settings Notes Number Minimum (default 50F) 50-99F - temperature range (in 1°F Cool Set 0610 increments) Temperature (default 10C) 10.0-37.0C (in 0.5C increments). Limit 12 hour clock Clock 0640 Format 24-24 hour clock No extended fan operation after call for heat Extended ends Not shown in Cool Only...
  • Page 47 Submenu Name Settings Notes Number When the touchpad is locked, the user/installer unlocked touchpad Touchpad 0670 needs to Lockout 1-locked touchpad press the system key for 5 seconds to enter 0–WiFi Off WiFi 0680 WiFi On selection 1– Temperature -9°F to 9°F (in 1F increments) -4.5°C to 4.5°C (in 0.5C increments) 0700 Display...
  • Page 48: Operation

    OPERATION Fig.23. Thermostat Keys Note: * Will not appear if setup submenu number 0160 is set for non-programmable (factory default)
  • Page 49 Fig.24. Thermostat Display Notes: * Only shows if Installer submenu number 0680 is set for WiFi (default) ** Displays as 12 or 24 hour clock selectable under Installer Submenu 0640. 12 hr is the default.
  • Page 50 User Setup Follow these steps to enter the User Setup: Press and hold the key for approximately 3 seconds until the screen changes. The submenu number displays at the bottom right corner. Press key to select the submenu, and press the key to enter the submenu.
  • Page 51 Table 3. User Setup Settings. Factory Defaults in Bold Submenu Description Settings Number 0140 version See Firmware version (display only) 0150 Date and time Current calendar date and time 0-backlight off during standby Backlight 0290 selection 1-backlight always on Fahrenheit Temperature 0320 Indication Unit...
  • Page 52 Submenu Description Settings Number unlocked touchpad Touchpad 0670 Lockout 1-locked touchpad 0-WiFi Off 0680 WiFi selection 1-WiFi On -9°F to 9°F (in 1F increments) Temperature -4.5°C to 4.5°C (in 0.5C increments) 0700 Display Offset 0°F (0°C) 0-no thermostat reset. Reset 0710 1-Resets all Installer Setup Options to default values and resets schedule to thermostat...
  • Page 53 Date/time Setting Enter USER SETUP, select submenu number 0150 and enter the date and time setting. Press to switch date to time in the following order: year, month, day, hour, and minute. Press to adjust the time. (You can advance the time more quickly by holding down the key or key buttons.)
  • Page 54 Setting the fan Press to select fan operation. Press again to select ON or AUTO (toggle to re-select). The selected option blinks. Press to save setting or press to exit without saving changes. ON: Fan is always on. AUTO: Fan runs only when there is a call for heating or cooling. Fig.26...
  • Page 55 Selecting the system mode Press to display options. Press again to select an option. You may need to press two or three times to make a selection—the selected option blinks. Press to save or press to exit without saving changes. Fig.27...
  • Page 56 Selectable system modes: HEAT: Controls only the heating system. COOL: Controls only the cooling system. OFF: Heating/cooling systems are off. AUTO: Selects heating or cooling depending on the indoor temperature. EMER (heat pumps with aux. heat only): Indicates manual activation of emergency heat. Compressor is locked out. Note: The AUTO and EMER system settings may not appear, depending on the type of ...
  • Page 57 Set Temperature Overrides The Lakepro-1 has two temperature override options: Hold Until and Permanent Hold. Hold Until Holds temperature set temperature temporarily until the next scheduled period time. Press key to adjust the temperature you want to set The word “Until”...
  • Page 58 Permanent Hold Keeps user set-point permanently until it is canceled manually. Press the key once. Screen shows Permanent Hold under the Set temperature. Press the key to adjust to the set temperature you want. To cancel, press the key again. Note: If the thermostat does not have a schedule (Installer Submenu 0160 is set to 0, factory default) the message Permanent Hold will always appear, indicating that the set temperature will not change until it is manually modified...
  • Page 59 Cleaning the Thermostat Screen The thermostat has a touch screen interaction. Follow these steps to clean the screen without making thermostat changes: Press and hold the key for approximately 3 seconds until the screen changes. The thermostat locks out all touch keys for 30 seconds to allow for cleaning and starts counting down.
  • Page 60 When the counter gets to 0, press the key to return to the Home Screen and normal operation. See Fig.29. Fig.29. IMPORTANT: Do not spray any type of liquid directly on the thermostat itself. If using household glass cleaner, spray the cleaner on a cloth. Then use the cloth to clean the thermostat screen.
  • Page 61 Screen Locks In User or Installer Setup, submenu 0670 allows you to prevent changes to all of the touchscreen functions. In this case, all keys are locked and nonfunctional, and the screen displays a lock icon continuously. To unlock keys and restore the touchscreen functions, press the System key for 5 seconds to enter installer setup and change the lock function with installer submenu 0670.
  • Page 62 Setting filter reminder intervals If activated during installation, the filter reminder alerts you by flashing “ ” on the screen above the time above the clock when it is time to replace your filter. Press after changing the filter, to restart the timer. To change the reminder interval: Press and hold the about 3 seconds until the screen changes.
  • Page 63 Note: Setup submenu 0500 governs the filter reminder interval. The days are counted based on fan run time, so anytime the fan is running, the reminder is counting that time against the number of days selected.
  • Page 64 Connecting to your Wi-Fi network To complete this process, you must have a smart phone connected to your home wireless network. If you get stuck... At any point in this procedure, restart the thermostat by removing the thermostat from the wall plate, waiting a few seconds, and snapping it back onto the wall plate.
  • Page 65 Please be sure your phone is connected to WIFI, and download the “TuyaSmart” APP from the App store or the Google PlayStore. Open the APP, sign up and Log in. Fig. 31. Fig. 32.
  • Page 66 Open the TuyaSmart APP, click “Add Device” or the “+” button on the top-right corner of the APP. Select Auto scan and the APP will automatically detect the thermostat, the Lakepro-1 should show up under ‘Available devices found’. Press ‘Next’.
  • Page 67 Fig. 34. Fig. 35. Select the Wi-Fi username and enter the password. Click “Confirm”. Note: You may receive a warning that this device only operates on 2.4 GHz routers (most routers have a 2.4 GHz channel). If you do cancel out of the warning page and continue.
  • Page 68 Fig. 36. Fig. 37. Wait for the thermostat to be added successfully. You may have to press ‘Done’.
  • Page 69 Note: If the thermostat connects to WIFI successfully, it will display the message above the room temperature, otherwise it will display The configuration needs to be finished within 3 minutes, otherwise the thermostat will quit the configuration mode. During step 4, if the APP did not automatically detect the thermostat, users can select “Add Manually”...
  • Page 70: Programming A Schedule

    PROGRAMMING A SCHEDULE If scheduling is enabled via Installer setup submenu 0160(comes disabled from factory), a schedule button will appear on the left of the screen and the thermostat will follow the default schedule shown on Table4. Table 4. Default Schedule Program Settings. Set points Schedule Period Time...
  • Page 71 Editing the default Heating and Cooling Schedule Your thermostat can control up to four different schedule periods per day: Wake – Start tim e of the period when you are awake and want your home at a comfortable temperature. Leave - Start time of the period when you go away from home and want an energy- savingtemperature.
  • Page 72 Editing the Schedule Press , and the screen will change. See Fig. 39 and 40. Fig.39. Fig.40. The time period being adjusted will appear on the bottom and the day of the week will appear on the top. First, the clock will blink, press to adjust the time.
  • Page 73 Repeat the above steps until completing the setting of the four time periods. Then, Press to turn to the next day, until you have completed the setting for the week. To end Schedule Programming, you may press the key to exit and confirm the program setting, or press to exit without saving changes.
  • Page 74 To Reset the Schedule You can reset the schedule to the default settings by pressing and holding the for approximately 3 seconds until the screen changes as shown in Fig.41. Then release key. The weekly schedule will be reset to the default schedule shown on table 4. Fig.
  • Page 75: Fcc Note

    FCC Note Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 76 particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna.
  • Page 77: Troubleshooting

    TROUBLESHOOTING Symptom Possible Cause Action Thermostat being Check for 24VAC between C and No LCD display powered. Check set temperature limits. The upper or lower set Check Installer Setup submenu temperature limits were 0600 or 0610, and modify as reached. needed.
  • Page 78 Symptom Possible Cause Action Thermostat minimum off- Wait up to five minutes for the time is activated. (Screen system to respond. displays ‘Wait’) System selection is not set to Set system Selection to correct Heating cooling Heat or Cool. value. does not come on.
  • Page 79 Symptom Possible Cause Action Thermostat is calling Check wiring. for Heat (Heat on) or Heating or cooling equipment Check Installer Setup submenu Cool (Cool on) but no is not operating. 0170 and make sure the correct heating or cooling. system type is selected. Set Fan Control in Heating to Fan does not turn on a Fan Control in Heating is set...
  • Page 80 Symptom Possible Cause Action Heat pump puts out Changeover Valve is not Set Changeover Valve (Installer cool air in heat mode configured match Setup submenu 0190) to match and warm air in cool changeover required by the the changeover required by the mode.
  • Page 81 Symptom Possible Cause Action Heating equipment is not a Set System Type (Installer Setup Heating equipment is heat pump but System Type 0170) to match the installed running in cool mode. (Installer Setup submenu heating and/or cooling 0170) is set to Heat Pump. equipment.
  • Page 82 Symptom Possible Cause Action System is not set to Heat Set the system setting to Heat The display does not and/or temperature is not and set the temperature setting show Heat On. above room temperature. above the room temperature. System is not set to Cool Set the system setting to Cool The display does not and/or temperature is not...
  • Page 84 1001 Park Centre Blvd Miami Gardens, Florida 305.471.7600 www.vtronix.com You can download a copy of this manual at https://vtronix.com/5-residential-thermostats...