Download Print this page
Universal Tool UT021A Operator Instructions

Universal Tool UT021A Operator Instructions

Advertisement

Quick Links

Operator Instructions
Includes - Foreseen Use, Work Stations, Putting Into Service, Operating,
Dismantling, Assembly and Safety Rules
Manufacturer/Supplier
Universal Air Tool Company Limited
Unit 8
Lane End Industrial Park
High Wycombe
Bucks
HP14 3BY
Tel No
(01494) 883300
Product Nett Weight
2.42
lbs
1.1
Kg
Air Pressure
Recommended Working
Recommended Minimum
Maximum
Personal Safety Equipment
Use - Safety Glasses
Use - Safety Gloves
Use - Safety Boots
Use - Breathing Masks
Use - Ear Protectors
Foreseen Use of Tool
This tool is designed for the purpose of driving staples for only the
sizes as indicated in the section "Operating". Do not use the tool for
any other purpose. Do not modify the tool to be used for any other
purpose or for its use as a stapler without first agreeing any such
modifications with the manufacturer or an authorised distributor.
Work Stations
The tool should only be used as a handheld, hand operated tool. It is
always recommended that the tool is used when standing on a solid
floor. It can be used in other positions but before any such use, the
operator must be in a secure position having a firm grip and footing
and be aware of a reaction force on the hand as result of the tool
doing work.
Putting Into Service
Air Supply
Use a clean lubricated air supply
that will give a measured air
pressure at the tool of 90
p.s.i./6.3 bar when the tool is
running with the trigger fully
depressed. Use recommended
hose size and length. It is
recommended that the tool is
connected to the air supply as
shown in figure 1. Do not
connect the tool to the air line
Fax No
(01494) 883237
Recommended Use Of
Balancer Or Support
No
6.3
bar
90
PSI
n/a
bar
n/a
PSI
7.0
bar
100
PSI
Yes
Yes
Page No 1
Important
Read these instructions carefully before installing, operating,
servicing or repairing this tool. Keep these instructions in a safe
accessible place.
Product Type
10mm Stapler
Model No/Nos
UT021A (HP021)
Recommended Hose Bore
Size - Minimum
3/8
Ins
10
M/M
Noise Level Sound Pressure Level 88.4 dB(A)
Peak C Level 116.0 dB(A)
Test Method Tested in accordance with ISO
Standard 3744
Vibration Level
Test Method Tested in accordance with ISO
standard 8662/1
system without incorporating an easy to reach and operate air shut off
valve. The air supply should be lubricated. It is strongly recommended
that an air filter, regulator, lubricator (FRL) is used as shown in Figure
1 as this will supply clean, lubricated air at the correct pressure to the
tool. Details of such equipment can be obtained from your supplier. If
such equipment is not used then the tool should be lubricated by
shutting off the air supply to the tool, depressurising the line by
pressing the trigger on the tool. Disconnect the air line and pour into
the intake bushing a teaspoonful (5ml) of a suitable pneumatic motor
lubricating oil preferably incorporating a rust inhibitor. Reconnect tool
to air supply and run tool slowly for a few seconds to allow air to
circulate the oil. If tool is used frequently lubricate on daily basis and if
tool starts to slow or lose power.
It is recommended that the air pressure at the tool whilst the tool is
running is 90 p.s.i./6.3 bar. The tool can run at lower and higher
pressures with the maximum permitted working air pressure of 100
p.s.i./7.0 bar.
RPM
N/A
Cycles Per Min
N/A
Serial No
Recommended Max.
Hose Length
30
Ft
10
M
Metres / Sec²
4.4

Advertisement

loading

Summary of Contents for Universal Tool UT021A

  • Page 1 Universal Air Tool Company Limited 10mm Stapler Cycles Per Min Unit 8 Lane End Industrial Park Model No/Nos Serial No High Wycombe UT021A (HP021) Bucks HP14 3BY Tel No (01494) 883300 Fax No (01494) 883237 Recommended Max. Product Nett Weight...
  • Page 2 Operating Dismantling & Assembly Instructions Disconnect tool from air supply. Grip body (19) in a vice fitted with soft jaws and remove air plug (32). Take out 2 off screws (38) and operate click lever (37) and slide off staple guide unit (43). Slide off pusher (42) and disengage from each end of pusher spring (41).
  • Page 3 UT021A (HP021) 10mm Stapler Ref No Part No Description Ref No Part No Description AB-50220 Hexagonal Bolt (6) AH-12515 Seal AL-11001 Exhaust Cover AL-11013 Trigger Valve Head AK-89165 Compression Spring AL-11014 Trigger Valve Stem AH-20012 Seal AH-03515 Special O-Ring AL-11002...
  • Page 4 Unit 8, Lane End Industrial Park, High Wycombe, Bucks, HP14 3BY, England declare under our sole responsibility that the product Model UT021A (HP021) 10mm Stapler, Serial Number to which this declaration relates is in conformity with the following standard(s) or other normative document(s) EN792 (Draft), EN292 Parts 1 &...

This manual is also suitable for:

Hp021