Ecoair DC18 MK2 User Manual

Ecoair DC18 MK2 User Manual

Compressor dehumidifier

Advertisement

DC18 MK2 / DC26
DC-100019
DC-100020
COMPRESSOR DEHUMIDIFIER
USER MANUAL
Please read instructions before use
Keep for future reference
Visit ecoair.org to register your product
or terms and conditions
@2021 EcoAir

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DC18 MK2 and is the answer not in the manual?

Questions and answers

Summary of Contents for Ecoair DC18 MK2

  • Page 1 DC18 MK2 / DC26 DC-100019 DC-100020 COMPRESSOR DEHUMIDIFIER USER MANUAL Please read instructions before use Keep for future reference Visit ecoair.org to register your product or terms and conditions @2021 EcoAir...
  • Page 2 WELCOME Thank you and congratulations for choosing an EcoAir dehumidifier to help you improve the air quality within your environment. Inside you will find many helpful tips on how to use and maintain your dehumidifier efficiently. Just a little preventative care can save you money and prolong the life of your dehumidifier.
  • Page 3: Table Of Contents

    Important Safety Instructions Refrigerant R290 BS Plug Wiring The Appliance and Accessories Important Safeguards Installation Setup Continuous Drainage Control Panel Operation 9 - 10 Emptying the Water Tank Cleaning, Maintenance and Storing the appliance Troubleshooting 13 - 14 @2021 EcoAir...
  • Page 4: Important Safety Instructions

    • Children and pets should be supervised to ensure they do not play with the appliance. • Do not use the appliance If the power cable, cord is damaged It must be replaced by an EcoAir’s Authorised Service Centre.
  • Page 5: Refrigerant R290

    Keep any required ventilation openings clear of obstructions. Never attempt to service or repair the appliances yourself, always ensure it is only serviced by EcoAir’s approved engineer using original EcoAir parts. If these appliances are installed, operated or stored in a non-ventilated area, then the room must be designed to prevent the accumulation of refrigerant leaks.
  • Page 6: Bs Plug Wiring

    If a 10A (BS 1363) fused plug is used it must be fitted with a 10A or 13A -fuse. If in doubt consult a qualified electrician. Please note the Earth, Neutral and Live Terminals are marked as E , N and L respec- tively. Page 3 @2021 EcoAir - V1.5 All rights reserved (E&OE)
  • Page 7: The Appliance And Accessories

    Control Panel Continuous Drainage Hose Air Outlet Carbon Filter Ambient Humidity Indicator User Manual Front Panel Castor Handle Air Inlet / Air Filter Back Panel Continuous Drainage Outlet Water Tank Page 4 @2021 EcoAir - V1.5 All rights reserved (E&OE)
  • Page 8: Important Safeguards

    • Dusty, building sites or an industrial environment where particles can clog up the filter or internal components. Page 5 @2021 EcoAir - V1.5 All rights reserved (E&OE)
  • Page 9: Installation

    If there is a problematic area or a room in a high humidity level, use a hygrometer to measure (available to purchase at ecoair.org) in the property, you may wish to place it in that area initially. Once the problem is settled you may wish to relocate to the location above.
  • Page 10: Setup Continuous Drainage

    1°C to avoid leakage. (When the outdoor temperature is at freezing point the water will not flow freely and this will cause a blockage consequently pushing the any condensation back to the dehumidifier and leakage may occur). Page 7 @2021 EcoAir - V1.5 All rights reserved (E&OE)
  • Page 11: Control Panel

    Blue denotes < 40%RH, Green denotes 40 - 60%RH, Red denotes > 60%RH. Indicator Description BLUE Humidity levels below 40% relative humidity. GREEN Above 40% and below 60% relative humidity. High humidity above 60% relative humidity Page 8 @2021 EcoAir - V1.5 All rights reserved (E&OE)
  • Page 12: Operation

    There is an active humidistat which shows the actual humidity level (%RH) in the environment when the dehumidifier is running. The display will show the actual humidity in the room a few seconds after the humidity level is set on the control panel. Page 9 @2021 EcoAir - V1.5 All rights reserved (E&OE)
  • Page 13 Note: We recommend to run Laundry Mode Sparingly as it could over dry your environment. 2hrs to 8hrs a day. Page 10 @2021 EcoAir - V1.5 All rights reserved...
  • Page 14: Emptying The Water Tank

    When cleaning the water tank, take caution to avoid damaging the float. • Do not tilt the dehumidifier when removing the water tank. This is to prevent water leaking which may cause electric shock. Page 11 @2021 EcoAir - V1.5 All rights reserved...
  • Page 15: Cleaning, Maintenance And Storing The Appliance

    6 months for optimal performance and hygiene standards. To purchase a replacement Note: If the filter is covered with dust, the airflow filter please visit: www.ecoair.org and the performance of the dehumidifier will be affected. STEP 3- CLEANING YOUR DEHUMIDIFIER STEP 4 - STORING YOUR DEHUMIDIFIER 1.
  • Page 16: Troubleshooting

    Room Temperature is too cold Increase heat in the room In the unlikely event of a problem with your product, please refer in the first instance to: ECOAIR TECHNICAL SUPPORT www.ecoair.org/support Page 13 @2021 EcoAir - V1.5 All rights reserved...
  • Page 17 Humidity sensor wet or failure. clean or replace the humidity sensor. play shows “E2” In the unlikely event of a problem with your product, please refer in the first instance to: ECOAIR TECHNICAL SUPPORT www.ecoair.org/support Page 14 @2021 EcoAir - V1.5 All rights reserved...