Summary of Contents for Lotus PCD-44G
Page 1
Installation and operating instructions GAS HOBS FOR PROFESSIONAL PCD-44G PCD-55G Model LIBR.ISTR.PCD-44G Code 563025400 Review 1 Edition date 20/04/2020 Language English LOTUS S.p.A. Via Calmaor, 46 31020 San Vendemiano +39 0438 778020 +39 0438 778277 Translation of the original instructions...
INTRODUCTION Components FIG. A 1 By-pass FIG. B 1 Pilot bracket screw 2 Pilot bracket 3 Pilot air bushing 4 Pilot injector 5 Injector screw 6 Spring 7 Extends drainage Translation of the original instructions...
Page 7
INTRODUCTION FIG.C (FLAMES) 1 Flame injector 2 Air adjustment 3 Pilot FIG. D Burner air adjustment Translation of the original instructions...
GENERAL INFORMATION 2 GENERAL INFORMATION Declaration of compliance The manufacturer declares that the appliances comply with the requirements of the regulation GAR 2016/426 for the gas part and directive 2014/30/EU,2014/35/EU for the electrical part. Installation must be performed in compliance with current regulations, especially with regard to ventilation of the premises and the exhaust gas evacuation system.
GENERAL INFORMATION Technical data table Technical data table PCD-44G RATED GAS FITTING MODEL DIMENSIONS TOTAL GAS FLOW (kW) ISO 7-1 PCD-44G 40x40x14h R 1/2GM PCD-55G 50x50x22h R 1/2GM Translation of the original instructions...
INSTALLATION 3 INSTALLATION Delivery checks On delivery, it is important to check the following: · External conditions of the packaging · The general status of the equipment · The conformity of the model with the information in the technical data plate and the instruction manual ·...
Page 11
INSTALLATION Note The ID plate is located in the compartment inside the door for appliances with compartments, or on the left side for appliances with an oven or a top. A second plate with the model and serial number is located inside the dashboard and a third is included with the certificate of conformity.
Page 12
INSTALLATION Warning Pressure is measured with a pressure gauge (minimum resolution of 0.1 mbar) mounted on the appropriate socket. Remove the M6 locking screw and insert the pressure gauge tube. The test must be performed with all the burners on the appliance switched on and all the appliances in the same line switched on.
Page 13
INSTALLATION 1 Extractor hood 2 Servo system - "B11" type devices (See data plate) Natural evacuation (fig.3) Connection to an efficient natural draft fume stack by means of a windproof connection, with discharge of combustion products directly to the outside ...
Page 14
INSTALLATION "B11" type appliances are supplied on request with a hood or a hood and windproof fume stack to be assembled and delivered separately. Translation of the original instructions...
INSTRUCTIONS FOR USE 5 INSTRUCTIONS FOR USE General information This appliance must only be used for its expressly intended purpose for cooking or heating food. Any other use is considered improper. The appliance is also intended for industrial use and must only be used by personnel trained for use and aware of the risks that the hot element entails.
INSTRUCTIONS FOR USE Switching the main burner off · Turn the knob into position . The burner turns OFF and only the pilot flame remains ON Turning the appliance off · Press and turn the gas cock knob to position "0". This control blocks the gas supply to both the main burner and the pilot burner ...
MAINTENANCE 6 MAINTENANCE Routine When using the appliance over time, it is essential to perform regular maintenance to ensure safe operation. We therefore recommend stipulating a service contract. Caution Maintenance must only be performed by specialist personnel in compliance with current ...
MAINTENANCE After conversion to another type of gas, update the technical data plate to indicate the type of gas for which the appliance has been converted. Minimum setting · After conversion to use another type of gas, or if a flame is too high when the knob is in position small flame), adjust the minimum setting by turning the by-pass screw.
CLEANING 7 CLEANING Routine cleaning Caution The use of flammable fluids to clean the appliance is forbidden To ensure hygiene and the durability of the appliance, perform external cleaning on a regular basis, taking care not to damage the cables and the electrical connections. Before starting cleaning, disconnect the appliance from the power supply.