Lotus PCD-44G Installation And Operating Instructions Manual

Gas hobs for professional use

Advertisement

Quick Links

Installation and operating instructions
GAS HOBS FOR PROFESSIONAL
USE
PCD-44G PCD-55G
Model LIBR.ISTR.PCD-44G
Code 563025400
Review 1
Edition date 20/04/2020
Language English
LOTUS S.p.A.
Via Calmaor, 46
31020 San Vendemiano
+39 0438 778020
+39 0438 778277
Translation of the original instructions

Advertisement

Table of Contents
loading

Summary of Contents for Lotus PCD-44G

  • Page 1 Installation and operating instructions GAS HOBS FOR PROFESSIONAL PCD-44G PCD-55G Model LIBR.ISTR.PCD-44G Code 563025400 Review 1 Edition date 20/04/2020 Language English LOTUS S.p.A. Via Calmaor, 46 31020 San Vendemiano +39 0438 778020 +39 0438 778277 Translation of the original instructions...
  • Page 2: Table Of Contents

    Contents Contents INTRODUCTION ......................... Installation drawing ........................Components..........................GENERAL INFORMATION......................Declaration of compliance......................Technical data table ........................INSTALLATION........................... Delivery checks ..........................Removing the packaging ......................Mechanical installation ......................... Electrical/gas connections ......................BURNERS TECHNICAL DATA TABLE (ITGB)................Burners technical data table ......................INSTRUCTIONS FOR USE......................
  • Page 3: Introduction

    INTRODUCTION 1 INTRODUCTION Installation drawing FIG. 1 PCD-44G C Gas connection Translation of the original instructions...
  • Page 4 INTRODUCTION FIG. 2 PCD-55G C Gas connection MODEL AIR INPUT (cm²) Translation of the original instructions...
  • Page 5 INTRODUCTION PCD-44G ≥ 100 PCD-55G ≥ 100   Translation of the original instructions...
  • Page 6: Components

    INTRODUCTION Components FIG. A 1 By-pass   FIG. B 1 Pilot bracket screw 2 Pilot bracket 3 Pilot air bushing 4 Pilot injector 5 Injector screw 6 Spring 7 Extends drainage   Translation of the original instructions...
  • Page 7 INTRODUCTION FIG.C (FLAMES) 1 Flame injector 2 Air adjustment 3 Pilot   FIG. D Burner air adjustment   Translation of the original instructions...
  • Page 8: General Information

    GENERAL INFORMATION 2 GENERAL INFORMATION Declaration of compliance The manufacturer declares that the appliances comply with the requirements of the regulation GAR 2016/426 for the gas part and directive 2014/30/EU,2014/35/EU for the electrical part. Installation must be performed in compliance with current regulations, especially with regard to ventilation of the premises and the exhaust gas evacuation system.
  • Page 9: Technical Data Table

    GENERAL INFORMATION Technical data table Technical data table PCD-44G RATED GAS FITTING MODEL DIMENSIONS TOTAL GAS FLOW (kW) ISO 7-1 PCD-44G 40x40x14h R 1/2GM PCD-55G 50x50x22h R 1/2GM   Translation of the original instructions...
  • Page 10: Installation

    INSTALLATION 3 INSTALLATION Delivery checks On delivery, it is important to check the following:   · External conditions of the packaging · The general status of the equipment · The conformity of the model with the information in the technical data plate and the instruction manual ·...
  • Page 11 INSTALLATION Note The ID plate is located in the compartment inside the door for appliances with compartments, or on   the left side for appliances with an oven or a top. A second plate with the model and serial number is located inside the dashboard and a third is included with the certificate of conformity.
  • Page 12 INSTALLATION Warning Pressure is measured with a pressure gauge (minimum resolution of 0.1 mbar) mounted on   the appropriate socket. Remove the M6 locking screw and insert the pressure gauge tube. The test must be performed with all the burners on the appliance switched on and all the appliances in the same line switched on.
  • Page 13 INSTALLATION 1 Extractor hood 2 Servo system   - "B11" type devices (See data plate)   Natural evacuation (fig.3) Connection to an efficient natural draft fume stack by means of a windproof connection, with discharge of combustion products directly to the outside  ...
  • Page 14 INSTALLATION   "B11" type appliances are supplied on request with a hood or a hood and windproof fume stack to be assembled and delivered separately. Translation of the original instructions...
  • Page 15: Burners Technical Data Table (Itgb)

    BURNERS TECHNICAL DATA TABLE (ITGB) 4 BURNERS TECHNICAL DATA TABLE (ITGB) Burners technical data table Burner technical data table PCD-44G 12.68 kWh/KG 12.87 kWh/KG 9.45 kWh/m3st.   BUTANE PROPANE METHANE H 30 mbar 37 mbar 20 mbar Burner max 10 kW-min 2,3 kW  ...
  • Page 16: Instructions For Use

    INSTRUCTIONS FOR USE 5 INSTRUCTIONS FOR USE General information This appliance must only be used for its expressly intended purpose for cooking or heating food. Any other use is considered improper. The appliance is also intended for industrial use and must only be used by personnel trained for use and aware of the risks that the hot element entails.
  • Page 17: Switching The Main Burner Off

    INSTRUCTIONS FOR USE Switching the main burner off · Turn the knob into position . The burner turns OFF and only the pilot flame remains ON   Turning the appliance off · Press and turn the gas cock knob to position "0". This control blocks the gas supply to both the main burner and the pilot burner  ...
  • Page 18: Maintenance

    MAINTENANCE 6 MAINTENANCE Routine When using the appliance over time, it is essential to perform regular maintenance to ensure safe operation. We therefore recommend stipulating a service contract.   Caution Maintenance must only be performed by specialist personnel in compliance with current  ...
  • Page 19: Minimum Setting

    MAINTENANCE After conversion to another type of gas, update the technical data plate to indicate the type of   gas for which the appliance has been converted. Minimum setting · After conversion to use another type of gas, or if a flame is too high when the knob is in position small flame), adjust the minimum setting by turning the by-pass screw.
  • Page 20: Cleaning

    CLEANING 7 CLEANING Routine cleaning Caution The use of flammable fluids to clean the appliance is forbidden     To ensure hygiene and the durability of the appliance, perform external cleaning on a regular basis, taking care not to damage the cables and the electrical connections. Before starting cleaning, disconnect the appliance from the power supply.