Prior to using this pump you must ensure that:
• The pump is installed in a safe and dry environment
• The pump enclosure has adequate drainage in the event of leakage
• Any transport plugs are removed
• The pipe-work is correctly sealed and supported
• The pump is primed correctly
• The power supply is correctly connected
• All steps have been taken for safe operation
Appropriate details for all of these items are contained in the following Installation and
Operating Instructions. Read these in their entirety before switching on this pump. If you
are uncertain as to any of these Installation and Operating Instructions please contact your
Davey Dealer or the appropriate Davey office as listed on the back of this document.
WARNING: Some insects, such as small ants, find electrical devices
attractive for various reasons. If your pump enclosure is susceptible to
insect infestation you should implement a suitable pest control plan.
Please pass on these instructions on to the operator of this equipment.
Dynaflo
Electric Pumps
Models: 60061R, 6200, 6210, 6220, 6230
Instructions
®

Advertisement

loading

Summary of Contents for Davey Dynaflo 60061R

  • Page 1 Operating Instructions. Read these in their entirety before switching on this pump. If you are uncertain as to any of these Installation and Operating Instructions please contact your Davey Dealer or the appropriate Davey office as listed on the back of this document. WARNING: Some insects, such as small ants, find electrical devices attractive for various reasons.
  • Page 2 In the event of installation difficulties or the need for further advice you 6. SUCTION PIPING should contact the Davey Dealer from whom you purchased the unit. Suction lift is made up of the actual vertical height Should you be unable to obtain the required advice...
  • Page 3: Power Connection

    The unused hole can be sealed by inserting the plug enclosed with the The Davey single phase pump motor is fitted pump. To connect a three phase Dynaflo pump with an inbuilt automatic reset thermal overload.
  • Page 4 9. PRIMING AND OPERATION A short four core flex (“D”) is fitted from the motor terminals (“E”). This lead is inserted through the The pump body and suction line should be Blanking Grommet (“F”). Pressure switch or other filled by pouring water into the priming plug control leads (“G”) can be fitted as well.
  • Page 5: Troubleshooting

    (16mm) socket spanner on end of shaft, check that motor shaft is free to turn. If not free, remove pump body and rectify cause of binding. 5. Internal motor fault: Have unit checked by your local Davey Dealer.
  • Page 6 * A Quick Reference Guide is included with the product when purchased new, for detailed instructions please visit daveywater.com, scan the QR code on the Quick Reference Guide / Davey product label (if applicable) or contact your local Davey Office.

This manual is also suitable for: