LIFE home integration SUPRA MB 6Mt 24 Vdc Instructions Manual

LIFE home integration SUPRA MB 6Mt 24 Vdc Instructions Manual

Road barrier 24vdc

Advertisement

SUPRA
MB 6Mt 24Vdc
RG1RE 24DL
ROAD BARRIER 24V
DC
INS T R UC T ION AND ADV E R T IS ING F OR US E AND MAINT E NANC E
1
Rev. 01 - 07/2017 LG

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SUPRA MB 6Mt 24 Vdc and is the answer not in the manual?

Questions and answers

Summary of Contents for LIFE home integration SUPRA MB 6Mt 24 Vdc

  • Page 1 SUPRA MB 6Mt 24Vdc RG1RE 24DL ROAD BARRIER 24V INS T R UC T ION AND ADV E R T IS ING F OR US E AND MAINT E NANC E Rev. 01 - 07/2017 LG...
  • Page 2 LIFE home integration si riserva il diritto di variare la caratteristiche tecniche in qualsiasi momento e LIFE home integration reserves the right to make changes to technical characteristics at any time and senza preavviso, mantenendo la destinazione d’uso e la funzionalità.
  • Page 3 Dis mantling of the barrier Manual releas e 180° ATTENTION...
  • Page 4 F ixing on the ground with bas e s ole ( SUE 2 ) 3 - Edit by closing Dx Remove Segher Remove the bracket Rotate the bracket by 90 ° Move the metal pin...
  • Page 5 C los ure to LE F T 45° Default production Open Stop Min.20° CLOSING LIMIT SWITCH OPENING LIMIT SWITCH WHITE Closed BROWN Stop GREEN GREEN Unlocked pos ition boom 45° SUM 3 Pz.1 Asta mt D. 80 mm Min.10° Position...
  • Page 6 45° C los ure to R IG HT Reversal pag. 4 cap. 4 Open Stop Min.20° CLOSING LIMIT SWITCH OPENING LIMIT SWITCH WHITE Closed BROWN GREEN Stop GREEN Unlocked pos ition boom 45° SUM 3 Pz.1 Asta mt D. 80 mm Min.10°...
  • Page 7 As s embly boom barrier mm 8 Mechanical stops adjus tment...
  • Page 8 COLLEGAMENTI CENTRALE CONNECTIONS • P rima di procedere agli allacciamenti e ai collegamenti leggere attentamente quanto riportato nel cap. PRESCRIZIONI E AVVERTENZE DI * Before commencing wiring and connection work, read the SAFETY INSTRUCTIONS AND WARNINGS and INSTALLATION INSTRUCTIONS SICUREZZA e PRESCRIZIONI E AVVERTENZE PER L’INSTALLAZIONE. AND WARNINGS.
  • Page 9 RG1RE 24DL RG1RE 24DL SKANT - SKANX SKANT - SKANX AERIAL AERIAL RG58-50ohm RG58-50ohm N.O. N.O. RELE’ 1 max 24V 1A RELE’ 1 max 24V 1A N.C. N.C. COMMANDS COMMON COMMANDS COMMON N.C. N.C. STOP STOP N.O. N.O. OPEN OPEN N.O.
  • Page 10 ATTENTION 230V 230V 230V 230V 2 PROGRAMMAZIONE DELLA CENTRALE 2 PROGRAMMING THE CONTROL UNIT F ASE 1 RESET DELLA CENTRALE P H ASE 1 TOTAL RESET 230V 230V 230V 230V 230V 230V PHASE 2 PROGRAMMING THE TRAVEL FASE 2 PROGRAMMAZIONE DELLA CORSA a) Premere per 5 secondi fino a quando i 5 led a) Press...
  • Page 11 GESTIONE DEL RADIOCOMANDO PROGRAMMING RADIO TRANSMITTERS 3.2 DELETE AND LEARNING REMOTE CONTROLS. LEARNING THE REMOTE CONTROL FOR OPENING. LEARNING THE SECOND RADIO CHANNEL RELAY1 DELETE OF A RADIO LEARNED DELETE OF ALL THE RADIO LEARNED...
  • Page 12 REGOLAZIONI E OPZIONI Richiusura automatica Automatic closing Viene attivata la richiusura automatica dopo un prefissato TEMPO PAUSA. Automatic closing is activated after a preset PAUSE TIME. In questa modalità impartendo il comando ‘ P ASSO’ l’automazione cambia il suo moto secondo la sequenza 1 – APRE 2 – PAUSA 3 – APRE4 – PAUSA In this mode by pressing the start button or radio transmitter the automation changes it motion as follows OPEN-PAUSE- CLOSE –...
  • Page 13 VELOCITA’ SPEED Con questo parametro si regola la velocià di apertura e chiusura della barriera. Premere il led rosso (SX) si accende. Press the red LED (SX) switches on. Premere per impostare i valori di velicità. Press to set the various speed values. SPEED LEDS ON LED ACCESI...
  • Page 14: Connection Cables

    Connection cables ALLACCIAMENTI E COLLEGAMENTI • Prima di procedere agli allacciamenti e ai collegamenti leggere attentamente quanto riportato nel cap. PRESCRIZIONI E AVVERTENZE DI SICUREZZA Fitters must make the connections of the 50 Hz 230 Vac electricity supply, and the various automation devices. e PRESCRIZIONI E AVVERTENZE PER L’INSTALLAZIONE.
  • Page 15 TROUBLESHOOTING DIAGNOSTICA This chapter describes the most frequently encountered problems with the solutions for resolving them. In certain cases, it is explicitly envisaged In questo capitolo sono riportati i problemi più frequenti con le soluzioni per eliminarli. In alcuni casi è previsto espressamente che le operazioni that operations be performed by a professional fitter: these indications must be followed in order to avoid exposure to serious risks.
  • Page 16: Safety Instructions And Warnings

    COLLAUDO E MESSA IN SERVIZIO TESTING AND TRIAL RUN • Il collaudo e la messa in servizio dell’automazione deve essere eseguita da una PERSONA COMPETENTE diretta e controllata da un INSTALLATORE PROFESSIONALE. • The testing and trial run must be performed by a COMPETENT PERSON supervised and aided by a PROFESSIONAL FITTER. It is the responsibility of the person who tests and sets up È...
  • Page 17: Installation Installazione

    LIFE home integration, allo scopo di migliorare i propri prodotti, si riserva il diritto di modificarli in qualsiasi momento e senza preavviso. Questo documento rispecchia lo stato dell’automazione alla quale With the aim of improving its products, LIFE home integration reserves the right to bring about alterations to them at any time, without giving prior notice. This document conforms to the state of the è...
  • Page 18 MAINTENANCE MANUTENZIONE 14.1 Maintenance instructions and warnings 14.1 Prescrizioni e avvertenze per la manutenzione • Once the automation has been tested, the parameters set must not be altered. If further adjustments (e.g. alterations to the voltage value) are made, ALL THE CHECKS REQUIRED FOR •...
  • Page 19: Mechanical Drawings

    Mechanical drawings...
  • Page 20: Declaration Of Conformity

    Declaration of conformity under Directive 98/37/EC, appendix II, part B (Manufacturer’s Declaration of CE Conformity) LIFE Home Integration Via S.Pertini 3/5 31014 COLLE UMBERTO (TV) declares that the following product: SUPRA MB 6Mt 24Vdc + RG1RE 24DL satisfies the essential requisites established in the following directives: •...