Product Safety Notices - Samsung PA43H4100AR Service Manual

Pdp tv
Table of Contents

Advertisement

Figure 1-1 : Leakage Current Test Circuit
4) With the unit completely reassembled, plug the AC line cord directly into a 120V AC outlet. With the unit's AC switch
first in the ON position and then OFF, measure the current between a known earth ground (metal water pipe, conduit,
etc.) and all exposed metal parts, including: metal cabinets, screwheads and control shafts. The current measured should
not exceed 0.5 milliamp. Reverse the power-plug prongs in the AC outlet and repeat the test.

1.1.4. Product Safety Notices

Some electrical and mechanical parts have special safetyrelated characteristics which are often not evident from visual
inspection. The protection they give may not be obtained by replacing them with components rated for higher voltage,
wattage, etc. Parts that have special safety characteristics are identified by
replacement that does not have the same safety characteristics as the recommended replacement part might create shock, fire
and/or other hazards. Product safety is under review continuously and new instructions are issued whenever appropriate.
Copyright© 1995-2013 SAMSUNG. All rights reserved.
on schematics and parts lists. A substitute
1. Precautions
1-2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents