ZT-2510 Series User Manual Warranty All products manufactured by ICP DAS are under warranty regarding defective materials for a period of one year, beginning from the date of delivery to the original purchaser. Warning ICP DAS assumes no liability for any damage resulting from the use of this product.
Table of Content 1 Introduction of ZigBee ....... 4 2 Introduction of ZT‐2510 ......5 3 Hardware Information ......... 6 3.1 Specifications ........6 3.2 ZT‐255x Front View ....... 7 3.3 ZT‐2510 Block Diagram ......8 3.4 ZT‐2510 Dimensions (Units: mm) ....8 4 Set up the ZT‐2510 module ......9 4.1 Introduction of configurations ....9 4.2 Connecting the Power and Host PC ....10 4.3 Configuring ZigBee Setting ...... 11 5 ZT‐2510 Applications ........
Page 3
If any of these items are missing or damaged, please contact your local distributor for more information. Save the shipping materials and cartons in case you want to ship the module in the future. More Information Documentation: CD: \Napdos\ZigBee\ZT_Series\Document http://ftp.icpdas.com/pub/cd/usbcd/napdos/zigbee/zt_series/document Software: CD: \Napdos\ZigBee\ZT_Series\Utility http://ftp.icpdas.com/pub/cd/usbcd/napdos/zigbee/zt_series/utility Page 3 ICP DAS, ZT‐2510 Series User Manual, Version 1.0 ...
Introduction of ZigBee ZigBee is a specification for a suite of high level communication protocols using small, low-power digital radios based on an IEEE 802.15.4 standard for personal area networks. ZigBee devices are often used in mesh network form to transmit data over longer distances, passing data through intermediate devices to reach more distant ones.
Introduction of ZT‐2510 The Basis of ZT-2510 Series Product The ZT-2510 series module is small-sized wireless ZigBee repeater based on the IEEE802.15.4 standard. It supports network routing and signal relay transmission function in a personal area ZigBee network. The typical transmission of ICP DAS ZT series ZigBee products is 700 meters (LOS, line of sight), with a transmission frequency range of between 2.405 GHz and 2.48 GHz,...
Hardware Information Specifications Part Number ZT-2510 (ZigBee Router) Configuration Interface Type B CA-USB18 (1.8 M Cable) x 1; USB Type A connector (Type A to Cable Type B cable provided) Compatibility USB 1.1 and 2.0 standard Driver Windows 98/ME/2000/XP/Vista/7/Linux 2.6.19 LED Indicator Display Green ZigBee Net...
ZT‐255x Front View System LED Indicator 2.4GHz RP-SMA Antenna UL 94V-0 materials USB Type B +10~+30 V Power input 1. LED Indicator of System: LED Indicator LED Color Explain ZigBee Net Green The status of ZigBee network. ZigBee RxD Yellow The status of ZigBee communication ZigBee PWR The status of module board...
ZT‐2510 Block Diagram LED Display ZigBee Module (Type B) (Slave) Power Circuit ZT‐2510 Dimensions (Units: mm) Front View Bottom View Left Side View Right Side View Page 8 ICP DAS, ZT‐2510 Series User Manual, Version 1.0 Copyright @ 2012 by ICP DAS Co., Ltd. All Rights Reserved. ...
Set up the ZT‐2510 module 4.1 Introduction of configurations “Pan ID” is the group identity of a ZigBee network, and must be the same if they are in the same ZigBee network. (Valid values range from 0x0000 to 0x3FFF) “Node ID” is the identity of the ZigBee module. The identity number must be unique if it is in the same ZigBee network as other ZigBee module.
“RF Power” is the transmit power. Code Note 0x0F Typical Maximum 0x08 Fit the CE/FCC certification 0x00 Typical Minimum ※ The parameter adjustment purely personal behavior, ICP DAS can not guarantee to pass CE/FCC certification if adjusting this parameter, nor assume any liability because of the adjustment parameters derived from the RF Power.
4.3 Configuring ZigBee Setting Launch the “ZT Configuration Utility” and click the [ZT Series] button. Click the [Serial Port] icon and then select the COM Port number. 1 After selecting the COM Port number, a list of model numbers will be displayed. Select the name of the module that you want to configure. After clicking the button, the utility will begin checking the connection.
Page 12
Once a connection is established, select either the [Default] or the [Wizard] function from the settings mode page. 4 Wizard Default Whether you select either the [Default] or the [Wizard] option for performing configuration, both are used to configure the Pan ID, Node ID, RF Channel, RF Power and so the relevant parameters.
ZT‐2510 Applications (1) ZT-2510 is suitable used in which environment is many obstacles and interferences. [ZigBee Router] [ZigBee End Device] WARNING HIGH VOLTAGE [ZigBee Coordinator] ZT-2510 [ZigBee Router] [ZigBee End Device] WARNING HIGH VOLTAGE [ZigBee Coordinator] Page 13 ICP DAS, ZT‐2510 Series User Manual, Version 1.0 Copyright @ 2012 by ICP DAS Co., Ltd. All Rights Reserved. ...
Page 14
(2) ZT-2510 is suitable used in which environment need to extend the communication range. [ZigBee Router] [ZigBee End Device] [ZigBee Coordinator] [ZigBee Router] [ZigBee End Device] [ZigBee Coordinator] ZT-2510 ZT-2510 (3) ZT-2510 is suitable used as redundant routing path. Page 14 ICP DAS, ZT‐2510 Series User Manual, Version 1.0 ...
Trouble shooting (1) LED Indicator Status: LED Indicator Status Introduction The status of ZigBee network [ZigBee Router (Slave)] Steady Lit Signal Strength ZigBee Net Blinking (500 ms) Signal Available (Green LED) Blinking (1s) Signal Weak Blinking (2s) Signal Terrible or No ZigBee Network The status of ZigBee communication ZigBee RxD Blinking...
Page 16
Please also provide a description of problem and attach file to an email and send it to service@icpdas.com Set the DIP switch of the ZT-255x device to the [ZBSET] position then reboot the device. Launch the ZT Configuration Utility and select [Save Log] icon to save the configuration of ZT-255x as a file.
Page 17
Technology Support If there is any question or concerns for using ZT-2000 series module, please feel free to contact us:Service@icpdas.com If there is any question or concern for using ZT-2000 series module, please feel free to contact us. ICP DAS will reply you within three days at most as possible as we can.