Microchip's family of Power over Ethernet Midspans (PoE) PD-96XXGC/AC and PD-95XXGC/AC inject power over
data-carrying Ethernet cabling. Employing these devices reduces the need for AC outlets, local UPS, and AC/DC
adapters near Powered Devices (PDs).
PD-9x06GC, PD-9x12GC, and PD-9x24GC/AC Midspans support 6, 12, and 24 ports respectively, in a
10/100/1000BaseTx Ethernet network, over TIA/EIA-568 category 5/5e/6 cabling. PD-96xxGC and PD-95xxGC
family devices can provide up to 90 W and 60 W respectively according to the new IEEE
power is supplied over both spare and data pairs of wires within a cable (1/2, 3/6, 4/5, and 7/8) to terminal units.
PoE Midspan normally powers devices that are PoE enabled or are equipped to receive power over Ethernet. These
devices are called Powered Devices (PDs).
PoE Midspans offer the following important features.
Safe and reliable power over an existing Ethernet infrastructure.
Remote management using web control and/or SNMPv3.
High-level of network security.
Safe solution that protects network infrastructure.
Standards compliant: IEEE 802.3bt.
Provides safe Power and Data over a single RJ45 cable.
©
2021 Microchip Technology Inc.
and its subsidiaries
PD-96XXGC/PD-95XXGC
Multiport Series User Guide
User Guide
®
802.3bt standards. DC
DS00004094A-page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Multiport Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Microchip Technology Multiport Series

  • Page 1: Introduction

    PD-96XXGC/PD-95XXGC Multiport Series User Guide Introduction Microchip’s family of Power over Ethernet Midspans (PoE) PD-96XXGC/AC and PD-95XXGC/AC inject power over data-carrying Ethernet cabling. Employing these devices reduces the need for AC outlets, local UPS, and AC/DC adapters near Powered Devices (PDs).
  • Page 2: Table Of Contents

    Troubleshooting Steps........................14 Specifications............................16 7.1. Physical Specifications.......................16 Microchip’s PowerView Pro........................17 Power Backup and Power Redundancy Connection................18 9.1. Power Redundancy........................18 9.2. Power Backup..........................18 9.3. Connectors..........................18 User Guide DS00004094A-page 2 © 2021 Microchip Technology Inc. and its subsidiaries...
  • Page 3 The Microchip Website..........................24 Product Change Notification Service......................24 Customer Support............................24 Microchip Devices Code Protection Feature....................24 Legal Notice..............................25 Trademarks..............................25 Quality Management System........................26 Worldwide Sales and Service........................27 User Guide DS00004094A-page 3 © 2021 Microchip Technology Inc. and its subsidiaries...
  • Page 4: Standards And Safety Guidelines

    Note:  Consult Microchip for a complete list of safety certifications. CE Marking CE marking on this product indicates that this product complies with the Electromagnetic Compatibility (EMC) Directive and Low Voltage Directive (LVD). User Guide DS00004094A-page 4 © 2021 Microchip Technology Inc. and its subsidiaries...
  • Page 5: Safety Information

    This unit operates under Safety Extra Low Voltage (SELV) conditions, according to IEC/EN60950-1 or ES1 according to IEC/EN 62368-1. Conditions are maintained only if the equipment to which the unit is connected also operates under SELV/ES1 conditions. User Guide DS00004094A-page 5 © 2021 Microchip Technology Inc. and its subsidiaries...
  • Page 6: Country-Wise Power Cord Specifications

    230 V (2P+T) via an isolation transformer with a 1:1 ratio, and with secondary connection point labeled Neutral and connected directly to ground. U.K. PoE Midspan is covered by General Approval NS/G/12345/J/100003, for indirect connection to a public telecommunications system. User Guide DS00004094A-page 6 © 2021 Microchip Technology Inc. and its subsidiaries...
  • Page 7: Information En Matière De Sécurité

    RJ45 à ces prises. Le câblage Ethernet connexe doit être limité à l'intérieur de l'immeuble. • Le câblage Ethernet associé doit être limité à l'intérieur du bâtiment. User Guide DS00004094A-page 7 © 2021 Microchip Technology Inc. and its subsidiaries...
  • Page 8: Data Input Ports

    The following sections detail the PD-96xxGC and PD-95xxGC port indicators. 4.5.1 PD-96xxGC/AC and PD-95xxGC/AC Midspan Series A bi-color (green and yellow) indicator per port indicates the port status. User Guide DS00004094A-page 8 © 2021 Microchip Technology Inc. and its subsidiaries...
  • Page 9 Green blinks once every 0.5 seconds Valid load. Total aggregated power Power is not connected to port. DC exceeds pre-defined power budget. voltage is not present on port output lines. User Guide DS00004094A-page 9 © 2021 Microchip Technology Inc. and its subsidiaries...
  • Page 10: Connectors

    Each data port is configured as data Pass-Through ports for all data pins (pins 1, 2, 3, 6, 4, 5, 7, and 8). Use cabling of Category 5 or higher. User Guide DS00004094A-page 10 © 2021 Microchip Technology Inc. and its subsidiaries...
  • Page 11: Poe Midspan Installation

    Midspan comes with 19-inch mounting brackets and screws. To install Midspan into a 19-inch rack: Remove the self-adhesive rubber feet from the bottom surface. Install the brackets using three screws per side. Note: Rack-mounting screws are not provided. User Guide DS00004094A-page 11 © 2021 Microchip Technology Inc. and its subsidiaries...
  • Page 12: Installation Factors

    Connect cables from IEEE 802.3BT ready terminals (PDs) to the corresponding DATA & POWER OUT ports (upper row on front-panel). Connecting Power Cables When using an AC source to power Midspan, plug-in the provided power cord to the back AC connector. User Guide DS00004094A-page 12 © 2021 Microchip Technology Inc. and its subsidiaries...
  • Page 13: Powering Up The Unit

    – Port indicators and power indicators illuminate in green. – Power indicator remains lit in green; port indicators are OFF. Ports are now ready (enabled) for normal operation. If LEDs are not lit, see Troubleshooting. User Guide DS00004094A-page 13 © 2021 Microchip Technology Inc. and its subsidiaries...
  • Page 14: Troubleshooting

    Midspan or on another one. If it works, there is probably a faulty output port or RJ45 connection. Verify that port shutdown command was not issued through Web management. User Guide DS00004094A-page 14 © 2021 Microchip Technology Inc. and its subsidiaries...
  • Page 15 Try to reconnect the same PD to a different port on the same Midspan or on another one. If it works, there is probably a faulty port or faulty RJ45 connection. User Guide DS00004094A-page 15 © 2021 Microchip Technology Inc. and its subsidiaries...
  • Page 16: Specifications

    PD-9612/24GC and PD-9512/24GC—950 W PD-9606GC and PD-9506GC—450 W Maximum output power per port PD-96xxGC—90W PD-95xxGC—60W DC input rated voltage PD-95XXGC/AC, PD-96XXGC/AC—53 V –57 V Input DC maximum current PD-95XXGC/AC, PD-96XXGC/AC—20 A User Guide DS00004094A-page 16 © 2021 Microchip Technology Inc. and its subsidiaries...
  • Page 17: Microchip's Powerview Pro

    Note:  The PD-96xxGC/AC and PD-95xxGC/AC Midspan comes with the PowerView Pro software pre-installed. In case the software needs to be re-installed or updated, the latest version is located in Microchip’s Software Library. User Guide DS00004094A-page 17 © 2021 Microchip Technology Inc. and its subsidiaries...
  • Page 18: Power Backup And Power Redundancy Connection

    Power backup and power redundancy control signal connector, COM D-Sub: 15 pins, 3 rows female connector. • DC voltage terminal block connector has two positive (+) terminals and two negative (-) terminals. User Guide DS00004094A-page 18 © 2021 Microchip Technology Inc. and its subsidiaries...
  • Page 19 Verify that the power indicator LED is ON (Green LED). Note:  When connecting a midspan to another midspan, connect the earth ground cable between both units Earth Ground connection. User Guide DS00004094A-page 19 © 2021 Microchip Technology Inc. and its subsidiaries...
  • Page 20 Redundancy, NMS View-Status window displays Power Source Status field. Power Source Status field shows both internal and external power supply statuses (green indication for OK and red indication for Fail). User Guide DS00004094A-page 20 © 2021 Microchip Technology Inc. and its subsidiaries...
  • Page 21 Note:  Midspan provides another power fail indication through Midspan's power indicator LED. Whenever unit's internal power supply fails, power indicator LED blinks once every second (Green LED). Figure 9-4. PD-95XXGC and PD-96XXGC Front Panel LED Indication User Guide DS00004094A-page 21 © 2021 Microchip Technology Inc. and its subsidiaries...
  • Page 22: Contacting Technical Support

    If you encounter any problems while installing or using this product, consult the Microchip technical support team through the website or contact on the following number: USA/Canada Telephone: +1 877 480 2323 Internet: www.microchip.com/support User Guide DS00004094A-page 22 © 2021 Microchip Technology Inc. and its subsidiaries...
  • Page 23: Revision History

    PD-96XXGC/PD-95XXGC Revision History Revision History Revision Date Description 07/2021 Initial revision User Guide DS00004094A-page 23 © 2021 Microchip Technology Inc. and its subsidiaries...
  • Page 24: The Microchip Website

    Attempts to break Microchip’s code protection feature may be a violation of the Digital Millennium Copyright Act. If such acts allow unauthorized access to your software or other copyrighted work, you may have a right to sue for relief under that Act. User Guide DS00004094A-page 24 © 2021 Microchip Technology Inc. and its subsidiaries...
  • Page 25: Legal Notice

    The Adaptec logo, Frequency on Demand, Silicon Storage Technology, and Symmcom are registered trademarks of Microchip Technology Inc. in other countries. GestIC is a registered trademark of Microchip Technology Germany II GmbH & Co. KG, a subsidiary of Microchip Technology Inc., in other countries.
  • Page 26: Quality Management System

    PD-96XXGC/PD-95XXGC Quality Management System For information regarding Microchip’s Quality Management Systems, please visit www.microchip.com/quality. User Guide DS00004094A-page 26 © 2021 Microchip Technology Inc. and its subsidiaries...
  • Page 27: Worldwide Sales And Service

    Tel: 631-435-6000 Sweden - Stockholm San Jose, CA Tel: 46-8-5090-4654 Tel: 408-735-9110 UK - Wokingham Tel: 408-436-4270 Tel: 44-118-921-5800 Canada - Toronto Fax: 44-118-921-5820 Tel: 905-695-1980 Fax: 905-695-2078 User Guide DS00004094A-page 27 © 2021 Microchip Technology Inc. and its subsidiaries...