Equipment Features - CEStronics AccessOne TSG8 Assembly And Operating Manual

Door controller
Table of Contents

Advertisement

6.2 Equipment features

Article description
Design
Performance parameters
Data interfaces
Communication
Inputs / Outputs (IN/OUT)
www.ces.eu
TSG8 / Compact (Art.-Nr 348007V)
Plastic housing for top-hat rail mounting
Fully stand-alone capable
4GB Flash memory , exchangeable, for
up to 200,000 locking media records
l
up to 100,000 events
l
Up to 255 minute-based day models with 3 time intervals
l
8 special day categories with own day model
l
40 special days with automatic calculation starting from Easter
l
Permanent opening/permanent locking time-controlled
l
dynamic, daily calculation of offline data
l
128 Bit AES encrypted communication
l
Entry / exit control
l
Door release time, door monitoring time, alarm delay and triggering programmable
l
from 0.1 ... 600 seconds
2-line LC display (display of network settings and operating parameters) / operation
l
via 1-button menu navigation
5x RS485, 1x RS232, 1x RJ45 (TCP/IP), 4x Wiegand
Support for up to 4 different reader protocols
UDP Port 10001
8 outputs:
configurable as potential-free NC contact / NO contact or active output
l
8 inputs:
4 analogue inputs for monitored potential-free signalling contacts, sensors, push-
l
buttons
4 digital inputs, optionally for potential-free contact or input voltage (12-24V) for
l
external signals, signalling contacts, sensors, push-buttons
Sabotage input for housing contact
l
Expandable via additional modules by 8 or 16 inputs/outputs up to 56 inputs/outputs

Advertisement