4.4 Protection:

If the power supply protection (OCP , OVP, or Short Protection) latches
off all main outputs, reset the PSU by cycling remote on/off control or
AC power.
4.4.1 Over Current Protection
Not over 240VA for every output voltage
4.4.2 Over Voltage Protection
+3.3V output : 4.5 Vmax
+5.0V output : 7.0 Vmax
+12.0V output : 15.6 Vmax
4.4.3 Short Protection
All output to GND.
4.5 Environment:
4.5.1 Operating Temp. +10 C to +50 C
4.5.2 Storage Temp. -20 C to +60 C
4.5.3 Operating Humidity 5% to 85%, non-condensing
4.5.4 Storage Humidity 5% to 95%, non-condensing
4.5.5 Operating Altitude 0 to 10,000 feet
4.5.6 Storage Altitude 0 to 50,000 feet
4.6 Hi-Pot: (Input/Output isolation)
4.6.1 Primary to Secondary
3535Vdc for
1 minute
4.6.2 Insulation Resistance
Primary to earth ground 500Vdc, 50M ohms Min.
Thermaltake Litepower Power Supply
11
>> >>
ATX1 2V 2.0 Version
Litepower 400W PSU
4.7 EMI & Safety
4.7.1 Conducted EMI
1. Meet FCC: Class B
2. Meet CISPR 22: Class B
4.7.2 Safety Standards
1. Meet UL/CUL
2. Meet TUV
3. Meet CB
4. Meet CE
5. Meet BSMI, FIMKO, SEMKO, DEMKO