2.0) BROODER SPECIFICATIONS
INPUT RATING
GAS SUPPLY PRESSURE
MANIFOLD PRESSURE
ORIFICE SIZE
MOUNTING HEIGHT
BROODER SPACING
BROODER SIZE
WEIGHT
VENTILATION REQUIRED
GAS CONSUMPTION
ELECTRICAL SUPPLY
3.0) BROODER CONTROL DESCRIPTION
Brooder Control No. 5 is designed for single or multi-zone installations using one or more thermostats. A
Zone Control (available as an accessory, Part No.43619050) is required to provide a 24-Volt power supply to
each brooder. The burner is controlled with a Direct Spark Ignition (DSI) switch, which is designed to provide
100 percent gas shut off of the main valve in the event that the main burner flame is not sensed.
42,000 BTU/h (12.31 kW)
Propane Gas:
42,000 BTU/h (12.31 kW)
Natural Gas:
42,000 BTU/h (12.31 kW)
Propane/Butane Mix Gas
11" – 14" W.C. (27.4 - 34.8 mbar)
Propane Gas:
Natural Gas:
11" – 14" W.C. (27.4 - 34.8 mbar)
Propane/Butane Mix Gas
10" W.C. (24.9 mbar)
Propane Gas:
Natural Gas:
10" W.C. (24.9 mbar)
Propane/Butane Mix Gas
5/64" (.0781")
Propane Gas:
3.1mm (.1220")
Natural Gas:
1.8mm (.0709")
Propane/Butane Mix Gas
Recommended - 72" (1830mm)
25' – 40' (7.6m – 12.2m)
35" (890mm)
Canopy Diameter:
13.75" (349mm)
Brooder Height:
21.5 lbs (10 kg)
Assembled Brooder:
168 CFM (286 m
Per Brooder:
0.46 GPH (1.75 L/hr)
Propane Gas:
0.42 Therm (44.3 MJ/hr)
Natural Gas:
0.46 GPH (1.75 L/hr)
Propane/Butane Mix Gas
24 VAC, 1 Ph, 60Hz, 0.8A
–2–
5" – 14" W.C. (12.4 - 34.8 mbar)
4" W.C. (10.0 mbar)
/hr)
3
Form No. 43539500
July 2021 A