PUMP
Bellows
Pump
Hose
Remaining
Hose
HEATER
1 Disassembly Top Plate, Control Panel,
Drawer Panel Assembly, Cabinet Cover
Assembly.
4 Remove pump outlet hose.
5 Remove tub pump bellows.
6 Remove cap(Remaining Hose).
7 Disconnect the wiring.
8 Three screws are unscrewed from the cabinet.
9 Remove the pump to arrow direction.
Rating : 220/240V 50Hz
Resistant : 162~176
1 Loosen the nut.
2 Remove washing heater by pulling out.
< Heater for Washing>
Rating : 230V 2000W
Resistant : 24.5~28.5
CAUTION
When assembling the washing heater, insert
the heater to heater clip on the bottom of tub
and check the position of wire color.