Table 5. Back view system status indicator LED behavior
Class
1000M Base-T LED
SFP+ LED
Table 6. Reset button behavior
Action
Press the Reset button for less than 5 seconds:
Press the Reset button for more than 5 seconds:
Table 7. Chassis physical design
Parameter
Height
Width
Depth
Chassis weight with factory-
installed components
NOTE:
Chassis weight does not include the weight of the power supply.
Table 8. Environmental parameters
Parameter
Operating temperature
Operating humidity
Storage temperature
Storage humidity
8
Introduction
Behavior
● Link LED - Green or amber
○ Solid green - Port is linked and running at maximum 1000M
○ Solid amber - Port is linked and running at lower 100M or 10M
○ Off - No link
● Activity LED - Green
○ Off - no port activity
● Link LED - Green or amber
○ Solid green - Port is linked and running at 10G speed
○ Solid amber - Port is linked and running at 1G speed
○ Off - No link
● Activity LED - Green
○ Off - no port activity
Behavior
● System reboots
● System reboots and system is reset to factory defaults
● Status indicator LED color changes to blue
● Flag indicating a long push is set by the BIOS in the CMOS RAM
● Flag allows user to have the operating system detect a long button
push
Configuration option 1
5.2 cm (2.0 in)
20.8 cm (8.1 in)
20.0 cm (7.9 in)
● 4-core: 1.44 kg (3.17 lb)
● 8-core: 1.42 kg (3.13 lb)
● 16-core: 1.44 kg (3.17 lb)
Configuration option 1
0–40°C (32°F–104°F) continuously
● 5% to 85% (RH), noncondensing
continuously
● 5% to 90% (RH), noncondensing short-
term (< 1% of operational hour per year)
–40°-70°C (–40° to 158°F)
5% to 90% (RH), noncondensing
speed on Base-T port
speed on Base-T port
NOTE:
The LED flashes green during port activity.
NOTE:
The LED flashes green during port activity.
Configuration option 2
5.2 cm (2.0 in)
20.8 cm (8.1 in)
20.0 cm (7.9 in)
● 8-core: 1.42 kg (3.13 lb)
● 16-core: 1.44 kg (3.17 lb)
Configuration option 2
0–40°C (32°F–104°F) continuously
● 5% to 85% (RH), noncondensing
continuously
● 5% to 90% (RH), noncondensing short-
term (< 1% of operational hour per year)
–40°-70°C (–40° to 158°F)
5% to 90% (RH), noncondensing
Need help?