When Replacing Eeprom (Memory) Ic - Toshiba 19DV616DG Service Manual

Lcd tv/dvd combination
Hide thumbs Also See for 19DV616DG:
Table of Contents

Advertisement

CONFIRMATION OF CHECK SUM, POWER ON TOTAL HOURS AND MICON VERSION
Initial total of MEMORY IC, POWER ON total hours and MICON VERSION can be checked on the screen. Total hours are
displayed in 16 system of notation.
NOTE: If you set a factory initialization, the total hours is reset to "0".
Please refer to "CONFIRMATION OF INITIAL DATA" when SUM DATA is not corresponding
1. Turn on the POWER, and set to the ALL mode.
2. Set the VOLUME to minimum.
3. Press both VOL. DOWN button on the set and Channel button (2) on the remote control for more than 2 seconds.
4. After the confirmation of each check sum, turn off the power.
NOTE: The each item value might be different according to each set.
Initial setting data check sum.
SCALER data check sum.
EEPROM check Version.
Main Micon check Version.
Sub Micon check Version.
CONFIRMATION OF INITIAL DATA
If a service repair is undertaken where it has been required to change the MEMORY IC, the following steps should be
taken to ensure correct data settings while making reference to INITIAL SETTING TABLE (Attached "INITIAL DATA").
1. Turn on the POWER, and set to the ALL mode.
2. Set the VOLUME to minimum.
3. Press both VOL. DOWN button on the set and Channel button (6) on the remote control for more than 2 seconds.
ADDRESS and DATA should appear as FIG 2.
NOTE: No need to set data other position than 0D00~0E3F and 1000~7FFF.
4. ADDRESS is now selected and should "blink". Using the UP/DOWN buton on the remote, step through the
ADDRESS until required ADDRESS to be changed is reached.
5. Press LEFT/RIGHT button to select DATA. When DATA is selected, it will "blink".
6. Again, step through the DATA using UP/DOWN button until required DATA value has been selected.
7. Pressing LEFT/RIGHT button will take you back to ADDRESS for further selection if necessary.
8. Repeat steps 4 to 6 until all data has been checked.
9. When satisfied correct DATA has been entered, turn POWER off (return to STANDBY MODE) to finish DATA input.
After the data input, set to the initializing of shipping.
10. Turn on the Power.
11. Set the VOLUME to minimum.
12. Press both VOL. DOWN button on the set and Channel button (1) on the remote control for more than 2 seconds.
13. After the finishing of the initializing of shipping, the unit will turn off automatically.
The unit will now have the correct DATA for the new MEMORY IC.

WHEN REPLACING EEPROM (MEMORY) IC

Version
Hardware version
Loader version
Software version
Enter
INIT
: 5BA5
VCT-P : B7AB LCD ON : 0000
EEPROM : W52P01CM00
ANALOG M : DB240_90306A
ANALOG S : DB210_81219A
ADDRESS
INIT
0000
LCD ON
ANALOG M : DB240_90306A
ANALOG S : DB210_81219A
FIG. 2
51.01
1.0
CB03C92051
Exit
FIG. 1
DATA
00
0000
C-3
C-3
Digital TV Hardware version
Digital TV Loader version.
Digital TV MICON Firmware version.
POWER ON total hours.
= (16 x 16 x 16 x thousands digit value)
+ (16 x 16 x hundreds digit value)
+ (16 x tens digit value)
+ (ones digit value)
19DV616DG
19DV616DG

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

22dv616dg

Table of Contents