  • Page 1 DANATRONICS DJ Series Videoscope Product Manual...
  • Page 2 Inspection technology for better future. Please read the manual before using the equipment.
  • Page 4 Declaration The manual is only intended to be used for the DJ Series As this manual is used a product series manual, the configuration and function of different products may slightly differ depending on your exact configuration. The technical specifications are only for reference.
  • Page 5: Table Of Contents

    MENU Instruction Before Use ................1 Main Configuration ................1 Button and Port ................... 3 Application ................... 5 After-service ..................5 Warning ....................5 1 Brief Introduction ................. 6 1.1 Parameters ................... 6 2 Operation Steps .................. 9 2.1 Take out the instrument ............. 9 2.2 Boot preparation .................
  • Page 6 3.5 Playback ..................14 3.6 Measuring function(optional, not standard configuration) ... 15 3.7 Zoom in/out ................. 15 3.8 Language setting ............... 15 3.9 Date&Time setting ..............15 3.10 Auto shut off ................16 3.11 Date Stamp ................16 3.12 Formatting ................16 3.13 Factory reset ................
  • Page 7: Instruction Before Use

    Instruction Before Use Main Configuration Instrument Case Micro USB/ charger Videoscope TF card reader Base(optional)
  • Page 8 For the specific configuration, please refers to the packing list. Name Specs Note Case 432*386*163 mm Videoscope 324.3*161.3*91.2mm Base 215*84*36mm Optional TF card reader Rechargeable Battery φ18mm×65mm Optional for 2pcs Micro USB Line Charger...
  • Page 9: Button And Port

    Button and Port working indicator ⑷ return ⑸ playback menu ⑴ ⑵ ok/function switch ⑹ up ⑺ down ⑶ brightness control ⑽ resetting ⑾ HDMI ⑻ front view/side view switch ⑿ TF card ⒀ Micro USB ⒁charging port ⑼ photo/video ⒂...
  • Page 10 (1) Menu: function setting including language setting/ time setting /firmware update. (2) Ok: in menu setting mode, it serves as a validation button; in preview mode, press ok button, it serves as function switch button. (3) Brightness control: control the light from 0-9 levels. (4)...
  • Page 11: Application

    (12) TF card: please use Class 10 or above TF card. Maximum: 32G. (13) Micro USB: When the monitor works independently, it serves as power input port. When it connects with power bank or mobile phone charging adapter, the monitor will turn on automatically. (14)...
  • Page 12: Brief Introduction

    ·Prohibit the use of this instrument to observe the body or the animal's body; ·Do not use the product to inspect equipment in action; ·Do not use or store the product on explosive, strong electromagnetic field or with combustible gas, otherwise it may cause fire or explosion; ·Do not use the product to check objects with current carrying, so as to avoid the occurrence of electric shock;...
  • Page 13 Illuminance Maximum:100000lx Tube Material Tungsten braided Tube Length 1.5m (customized for other length) Protecting Device of buffer protection device between the host and Durability wear-resistant tube Articulation 360° all way Bending Angle ≥160° damping positioning (optional: articulation Probe Positioning locking device) 5.1 inches color IPS display, all sight viewing Display angle...
  • Page 14 Power Consumption Power Charge DC5V, maximum current:1A Weight 0.55~0.8kg (including 2 batteries) replaceable monitor and tube with different Compatibility diameter Store Temperature -23℃~63℃ Relative Humidity maximum: 92%, non-condensing Monitor Working -30℃~60℃, when 0°C below, the display needs Temperature preheating. Camera Working -25 ℃...
  • Page 15: Operation Steps

    2 Operation Steps Take out the instrument When removing the instrument from the case, be careful to not kink the cable or scratch the camera lens 2.2 Boot preparation Check to be sure the insertion tube is connected to the monitor, the SD card and batteries are installed (one battery also works normally).
  • Page 16: Operation

    * Lock the button on the back of the monitor; (4) * Install the SD card. 2.3 Operation The DJ Series has10 levels of brightness adjustment. Press the light control button to change the level. Slowly insert the tube to the inspected object. The operation interface is as follows:...
  • Page 17: Probe Articulation Control

    2.4 Probe articulation control According to the testing need, operate the joystick to control probe articulation. The bending motion of the front probe is controlled by rotating the joystick. During operation, if the joystick suddenly meets resistance, or there is any abnormity, please immediately stop using.
  • Page 18 operation, the user is responsible for the damage. Turn off the power switch, put the instrument into the portable case carefully, and put the tube into the case.
  • Page 19: Image Capture And Operation

    3 Image Capture and Operation 3.1 Photo/Video ① Short press “(9) photo/video button”; ② The image will freeze a frame, indicating a photo has been captured and saved automatically. The saved file is named in the form of Date+No. Such as: 20170725 001.JPEG ③...
  • Page 20: Image Special Effects

    Temperature indicator is on the upper left of the screen. When the testing temperature is 20℃~64℃, it indicates in green color. Orange alarm when the probe temperature is 65℃~79℃; red alarm when above 80℃. For the protection of the probe and camera, the monitor will shut off automatically. 3.3 Image special effects In preview mode, press “(2) OK”...
  • Page 21: Measuring Function(Optional, Not Standard Configuration)

    3.6 Measuring Function In preview mode, press “(2) OK” button, select , which stands for measuring prohibited function. Press “(6) up” button or “(7) down” button to swift to start measuring function. Press “(6) up” button or “(7) down” button again to close it.
  • Page 22: Auto Shut Off

    3.10 Auto shut off In preview mode, press “(1) menu” button to enter menu dialog box. Select “Auto shut off” menu by pressing “(6) up” or “(7) down” button. Then press “(2) OK” button to pop up shut off time and function option box, press “(6) up” or “(7) down”...
  • Page 23: Solution To Common Problems

    software files on the SD card (do not place it in folders or change bin file name). Enter the setting interface, select firmware upgrade, it will be black screen. After the screen indicator light goes out, turn off the monitor, reboot and enter new system interface.