Appendix; Reference Part List; Grounding Strategy - Bosch INTELLIVOX DDC LBC 325 Series Installation Manual

Active line array loudspeakers
Hide thumbs Also See for INTELLIVOX DDC LBC 325 Series:
Table of Contents

Advertisement

Intellivox DDC | Installation Manual | Appendix
3.

Appendix.

3.1 Reference part list.

Connectors for external wiring.
Terminal
Description
RS-485
Wago cage clamp connector 5 pin
female 5 mm pitch
Audio input
Wago cage clamp connector 6 pin
female 5 mm pitch
Failure, Fan, Ambient
Wago cage clamp connector 5 pin
SPL and Temperature
male 5 mm pitch
Table 3 Intellivox external connectors details.
Other installation related accessories.
Description
Intellivox swivel bracket 90°
Intellivox swivel bracket 45°
Ambient mic. and temperature sensor LBC 3262/00
Table 4 Specific installation related accessories.
Other network related accessories.
Description
Program set
(Adapter cable+RS-232 to RS-485
adapter+ WinControl CD-Rom)
Table 5 Specific network related accessories

3.2 Grounding strategy.

The ground (GND) terminals on the electronics
module serve different purposes.
1. Safety. The GND terminal located at the mains
IEC connector provides a direct low impedance
path from the metal parts of the chassis to ground.
In conjunction with a proper designed mains
distribution network, this offers extra safety in
situations where the standard class 2 insulation is
not sufficient (fire, moisture etc.). Always connect
the IEC ground terminal.
Bosch Security Systems | July 2003
All manuals and user guides at all-guides.com
2. Reduction of RF emission. Although the
Type Number
LBC 3270/00
LBC 3271/00
3. Immunity. The GND terminal shorts currents
To make things even more complex, the RS-485
terminal of the chassis also has a DGND pin, while the
ambient SPL/temperature terminal has both GND and
Type Number
AGND pins.
LBC 3260/00
The pins labeled GND are connected directly to the
chassis.
The RS-485 DGND pin is not a ground pin, but serves
as a reference for the RS-485 AB and YZ wires.
Although the DGND pin should be connected to the
shielding of the RS-485 cable (when in use), DGND
(and ABYZ) has no relation to GND except for the
fact that the voltage between DGND and GND is
clamped to a maximum voltage of 50 V for reasons of
safety and immunity. In an installation with a
connected network, the RS-485 cable shield must be
grounded at some central position.
Manufacturer
Manufacturer code
WAGO
231-105/026-000
WAGO
231-106/026-000
WAGO
231-605
Intellivox electronics module is well shielded and
external connections are de-coupled to prevent RF
emission from the internal high speed digital
circuits, this protection will not work properly when
the chassis has no solid ground reference.
which are induced by (RF) fields in the signal
cables effectively to chassis-ground, provided that
the cable shield is of sufficiently low impedance.
DGND should not be connected to any other
ground pin (GND or AGND) on the chassis.
EN | 13

Advertisement

Table of Contents
loading

Table of Contents