• Compressor surface becomes very hot during operation. Mount away from flammable materials and avoid locations where it may be accidently touched while operating. • Rated for 12 V DC systems only. For product warranty please refer to our website www.tjm.com.au 29/05/2019 Page 1 of 12...
26 A Current Draw (200 kPa / 29 PSI) 33 A Fuse Type and Rating Maxi 40 A IP Rating Motor thermal cut-off 105°C For product warranty please refer to our website www.tjm.com.au 29/05/2019 Page 2 of 12 File: F-17800.docx...
2.1 Accessory Installation Installation Conditions: The 12 V solenoid shown is supplied with the TJM Pro Locker. The ¼” BSPT hose fitting shown is supplied with the TJM Airline Kit o Determine the desired mounting configuration for the compressor and select the desired outlet ports for the accessories –...
Page 4
Remove the protective plug from the compressor inlet port. o Screw the filter housing into the port. Hand tighten only. For product warranty please refer to our website www.tjm.com.au 29/05/2019 Page 4 of 12 File: F-17800.docx...
Notes: Check the Air Filter elements at frequent intervals. If Air Filters become damaged, wet, or dirty, DO NOT use the compressor until air filters are replaced. Contact a TJM Distributor for service. 3.0 Vehicle Mounting 3.1 Mounting Location When deciding an appropriate place to mount the compressor within the vehicle, consider the following: o Avoid proximity to heat sources;...
Page 6
Secure the base-plate and backing plates to the vehicle using M6 or M8 bolts, spring washers and nuts (not included with the compressor). If using M6 bolts, ensure the washers adequately cover the base-plate surface. For product warranty please refer to our website www.tjm.com.au 29/05/2019 Page 6 of 12...
This prevents unexpected handling changes from accidental Front Locker activation. TJM recommends wiring the Red/Yellow +12 V wire to the Ignition circuit to reduce likelihood of compressor draining the battery. It is possible to wire to the Accessory circuit instead.
Page 8
Notes: If additional wire is required to reach the battery, use 10 AWG wire or larger. 4.2 Electrical Diagram Figure 1: TJM Vehicle Mount Compressor Recommended Wiring Diagram For product warranty please refer to our website www.tjm.com.au 29/05/2019 Page 8 of 12...
□ Compressor operational check completed. □ Leak Test completed. □ Compressor safely mounted using appropriate hardware. □ Wiring Loom installed according to the TJM Diagram. □ Air lines securely installed. □ Switches hard-mounted to dash and out of reach of accidental activation.
Page 10
Discharged air will contain moisture due to air humidity. When using the compressor in conjunction with an on-board air tank, TJM recommends installing a moisture trap before the air tank inlet and/or fitting the air tank with a drain valve.
013COMPVMOUNTKIT – Replacement rubber isolator and bolt kit o 013COMPVSRV155-18N – Safety relieve valve 155 PSI, male ⅛” NPT o 013COMPVPS120-90 – Pressure switch OFF 120 PSI / ON 90 PSI For product warranty please refer to our website www.tjm.com.au 29/05/2019 Page 11 of 12...
Page 12
Tighten all mount bolts. This is a basic guide for field troubleshooting only. If the compressor does not operate after taking these steps, refer to a TJM distributor. For product warranty please refer to our website www.tjm.com.au 29/05/2019 Page 12 of 12...
Need help?
Do you have a question about the 013COMPVHD and is the answer not in the manual?
Questions and answers