Wiring Diagram And Block Diagram; Wiring Diagram - Mitsubishi MJ-E16S-S1 Service Manual

Table of Contents

Advertisement

6. Wiring Diagram and Block Diagram

6.1 Wiring Diagram

E16S
Run capacitor
Power plug
E16SX
Run capacitor
Power plug
Safety Devices
(1) Current fuse ....................Overcurrent flow caused by deterioration in electrical parts or other problems
(2) Motor protector................Current flow exceeding 1.7A with compressor surface temperature of approx.
(Overload relay)..............100°C shuts down compressor operation.
(3) Control circuitry ...............The room temperature thermister senses temperature below about 0°C, and
(4) Thermal fuse ...................When blower motor temperature exceeds 134°C due to blower locking or other
12
C
CM
R
FM
S
P5
P2
Gray
P4
Gray
Blue
Power supply board
P1
Brown
C
R
CM
FM
S
P5
P2
Gray
P4
Gray
Blue
Power supply board
P1
Brown
turns the power source to OFF.
<Current setting: 2A>
The compressor will also shut down when malfunctions or other problems
cause the current flow to exceed 4.7A.
shuts down the compressor.
malfunctions, blower operation shuts down.
SV
Control board
P200
P3
P100
P10
P11
White
White
Gray
P13
Gray
SV
Control board
P200
P201
P100
P101
P3
P10
White
P11
White
P20
P13
Gray
Gray
Sensors
(Humidity and room
temperature sensing)
1°C (defrost)/12°C (end)
Thermistor (Tube
temperature sensing)
Tank full switch
Sensors
(Humidity and room
temperature sensing)
1°C (defrost)/12°C (end)
Thermistor (Tube
temperature sensing)
SM
Stepping motor
Tank full switch

Hide quick links: