Accelera�On & Decelera�On Parameters - Hitachi P1 Basic Instruction Manual

Hide thumbs Also See for P1:
Table of Contents

Advertisement

AC CE LE RA T ION & DE CE L E RA TI ON P AR AM E TE R S
Standard Accel & Decel Func�ons
Accelera�on Time (1)
Decelera�on Time (1)
The Hitachi VFD's features two-stage accelera�on and decelera�on ramps. This gives flexibility in the profile shape while running in
the infinite variable method. This feature allows you to have more control in the accel and decel while transi�oning your frequency.
You can specify the frequency transi�on point, the point at which the standard accelera�on (AC120) or decelera�on (AC122)
changes to the second accelera�on (AC124) or decelera�on (AC126).
Use the table below to configure the 2-Stage Accel & Decel feature.
2-Stage Accel & Decel Func�on
Accelera�on Time (2)
Decelera�on Time (2)
Select method to switch
to accel / decel (2) profile
Accel (1) to Accel (2) frequency transi�on
Decel (1) to Decel (2) frequency transi�on
12/17/2018
Hitachi P1 Closed Loop Hoist Basic Instruc�on Manual Firmware V19 – V25
VFD Parameter
AC120
AC122
VFD Parameter
AC124
AC126
AC115 = 00 will require the use of CA-06 = 031
AC115 = 01 will use transi�on frequency
AC115 = 02 will change when direc�on is reversed
AC115
AC116
11