Download Print this page

Hangzhou Qifei Intelligence Technology A16 2020 Manual page 4

Agriculture drone intelligent flight battery

Advertisement

Abnormal Status Indicator
LED5 Red, LED6 Orange, LED7 White
Red
Orange
LED5
LED6
on
on
blinking
on
Tips:
A.
In order to prevent the battery from over-discharging, the battery will sleep when the
battery level is less than 10%. At this time, the charger cannot be charged automatically
when it is plugged in, and the battery needs to be turned on manually to charge.
B.
If the battery temperature exceeds 55 degrees Celsius, the battery high temperature alarm
will be triggered. You need to wait for the battery temperature to drop below 55 degrees
before charging.
C.
In the fast charge mode, in order to protect the battery and prolong the battery life, the
single-chip cell voltage stops charging at 4.15. At this time, the battery power does not
reach 100%, and the battery indicator may flash LED4, but it does not affect the battery
life.
D.
E. If the battery is not used for more than 5 days in a fully charged state, in order to extend
the life, the battery will automatically discharge to a safe voltage for storage, and the
battery temperature may rise during the discharge process.
E.
If the battery is not used after it is turned on, the battery will automatically shut down
after 10 minutes.
APP Battery Management (Only Available in China Mainland)
If using a charger with 4G network function and adding a charger,Users can view the battery
history and real-time statistics of the connected or connected charger in the AGRAPP
Application Scenario:
When you need to count the number of abnormal batteries of all batteries under the user name;
Battery level when last minute online ; the number of cycles and other information, Users can
quickly view, count, and manage the battery through the battery management function; It is
convenient for users to quickly candidates abnormal, fully charged, need to charge, over-charged
White
LED7
on
Battery voltage difference Primary alarm:
Voltage Difference≤300mv
Battery voltage difference Secondary alarm:
Voltage Difference≥300mv
Battery voltage is too low
blinking
Charging temperature Primary alarm:
Charging temperature Secondary alarm:T>75℃
on
Overcharge and other errors
Status
50℃≤T≤75℃
Processing
Please balance before
using
Please balance before
using
Please charge
immediately
Please cool down
before using
Please cool down
before using
Do not use

Advertisement

loading

Related Products for Hangzhou Qifei Intelligence Technology A16 2020