Download Print this page

White Balance - TCL 49S62FS Service Manual

Hide thumbs Also See for 49S62FS:

Advertisement

2.3. White Balance

White Balance Touch-Up (Golden sample)
As some color coordinates discrepancies can be noticed from panel batches to others, it may necessary to perform
slight touch-up.
For Color temperature adjustment, switch TV on leading HDMI input where should be connected suitable generator
providing following format 1280x720p@60Hz test pattern. A 32 steps grey scale is recommended to assess relevant
colorimetry tracking and low/high light saturation points.
Ensure that TV's picture enhance is off.
Ensure that TV is in Factory mode to access to "White Balance" adjustment submenu , then scroll down to
toggle off "Pic. Enhance" flag.
WB Normal is the first mode which is adjusted in HDMI source,the next are HDMI warm and cool mode.
Warm and Cool Tone are relatives to Normal mode. WB adjust need to fix default G Gain .Offset registers needn't
to be adjusted.
"Gain" registers set need to be adjusted at 70IRE.
Targets and Tolerances for all inputs
(According to company uniform LED color temperature standard of panel)
The measured and adjustable parameters should be mainly "x", "y" coordinates.
The White Balance alignment should be performed using a well calibrated and contact less analyzer (ex: Minolta
CA210 or CA310). The analyzer may not touch the screen surface, and measurement must be performed in a dark
environment keeping the probe(s) at 90+/-2° from the panel center.
The results should fulfill specification for each TV set offered by R&D and below tolerances::
NT72563
panel name
Model
43D2900
ST3151A05-9
新建文件夹 (3)Test and Alignment Specification for NT63
Energy
FW Min (Nits) Preset Targets (x, y)
Efficient
FW>Min
A+
250
Page 12 of 25
COOL
NORMAL
Series (v0 01) 170612