Download Print this page

TCL 32S6S Service Manual page 20

Advertisement

Targets
COOL
Coordinate "x"
Coordinate "y"
Important: If measurements are performed on whatever else LED panel with Minolta CA210, it's required to
calibrate additional channel (ex: CH01) using relative following offsets (CH00 remains for CCFL panel):
for "
".
+0.012
y
and
See WB list as follows for more details.
Note④:
Cloning
Once a TV is well aligned and prepared (channels maps, volume, picture presets...), user can prepare golden clone
image that can be copied on demand to all further TV production lot of same TV. To access cloning function, you can
select "Factory menu USB Clone && Update", Scroll down to "TV to USB" or "USB to TV" and press RCU "OK/►"
key to process. 4 BIN images will be created, overwritten or read on USB stick (pen drive) depending on chosen
template like following: "database\database\***.db". These files need to be used strictly with MT5655 SoC platform as
depending on SW structure.
Other faster access methods via UART/IR commands are available on enclosed SIACP requirements (rev. v3.9).
2.4. High Pot and Insulating Resistance Tests
At the end of the process, a "High Voltage" and an "Insulating Resistance" tests are required to fulfil Safety
Electrical requirements (CEI 65065).
▪ High Voltage Withstanding requirements
- "Voltage"
- "Max Leakage Current"
- "Test Time"
2.5. SHOP-END Test
At final process stage, it's necessary to perform "Reset shop" before any packing to leave Factory mode and
restore User default presets.
This function is accessible by selecting "Factory menu Reset Shop", then pressing RCU "OK/►" key. Other
faster methods via UART/IR commands are available on enclosed SIACP requirements (rev. v5.4).
新建文件夹 (3)Test and Alignment Specification for NT63
NORMAL
engineer
Offered by R&D PQ
3500 VAC
10 mA
3 sec
Page 13 of 25
Tolerances
WARM
ALIGNMENT
± 0.003
± 0.003
▪ Insulating Resistance requirements
- "Voltage"
- "Threshold Min"
- "Test Time"
Series (v0 01) 170612
MEASUREMENT
± 0.020
± 0.020
for "
+0.002
500 VDC
4M Ω
2 sec
"
x