2. Product Assembly (PA): Test & Alignment

2.1. Factory Menu

Follow the below steps to pop-up the Factory menu in case of "Factory hotkey" is disabled:
- Press RCU "MENU" key to display Setting menu
- Select Picture
- Scroll down to "Contrast" item
- Press the subsequence RCU keys "9", "7", "3" and "5"
In case of "Factory hotkey" is enabled, just press RCU "Return" key(
The status of "Factory Key" can be changed in "Factory Menu->Hotkey"
Press RCU "OK/►" key to enter the submenu.
Press RCU "Menu" key to go back to the root menu.
Press RCU "◄/►" key to change the values.
Press RCU "OK" key run the function.
Press RCU "Exit" key exit the Factory menu.
Factory Captions Description
While "Factory hotkey" is enabled, there's some toggled display information (~2s) relative to SW, Project ID,
CI+, Network ID to facilitate 100% quick screening without accessing to whatever else menu:
Main SW Ver
Project ID (ID)
ERG(PVR)
CI Key Activation flag (CI+ key)
MID(Internet infor for factory)
P (Production/Factory mode flag) / S (Factory UART Parser mode flag) / W (Warm-Up mode flag)
"Factory Menu Description"
See Appendix
2.2. Warm-up Test
Following TCL standard and practices, it's required minimum 15min of Warm-Up that can be considered as Burn-In.
Additional Aging for White Balance alignment is no more necessary due to consistent Picture Performance with
Cloning usage.
This function is accessible by selecting "Factory menu WARM UP", pressing RCU "OK/►" key and then leaving
Factory menu by pressing "Exit" key. To release/disable Burn-in mode, it's just required to press "Menu" button from
local keyboard. Other faster methods via UART/IR commands are available on enclosed SIACP requirements (rev.
v5.4).
新建文件夹 (3)Test and Alignment Specification for NT63
Page 11 of 25
Series (v0 01) 170612
) to pop-up again the Factory menu.