ADJUSTMENTS
■ ■ ■ ■ SCREEN ADJUSTMENT
Measuring
Item
instrument
SCREEN
Remote
adjustment
control unit
■ ■ ■ ■ OSD HORIZONTAL POSITION ADJUSTMENT
Measuring
Item
instrument
HORIZONTAL
Remote
POSITION OF
control unit
OSD
adjustment
SERVICE MENU SCREEN
JVCAK30/37
OSD
059
IF1
004
IF2
065
IF3
004
IF4
065
AGC
033
VLIN
044
RGBH
005
VSOF
+05
VPOF
-01
: 1
1
X
Screen size
■ ■ ■ ■ IF ADJUSTMENT
Measuring
Item
instrument
IF adjustment
Remote
control unit
Test point
Adjustment part
SCREEN VR
[On the FBT]
Test point
Adjustment part
OSD
B04
Reference bar
X'
Test point
Adjustment part
IF 1
IF 2
IF 3
IF 4
1. Enter SERVICE MENU.
2. Press YELLOW key to disable vertical scan.
3. Adjust SCREEN VR. on the FBT as thin as possible.
4. Press YELLOW key again to enable vertical scan.
5. Press STANDARD key to leave service menu.
FBT
1. Enter SERVICE MENU.
2. Select OSD (On screen display) with FUNCTION ( / ) key
3. Adjust the OSD horizontal position with the FUNCTION (
key, which shifts the reference bar on the bottom of
SERVICE MENU horizontally, so that the OSD is positioned on
the screen center. (X=X')
1. Receive a PAL colour bar pattern.
2. Enter SERVICE MENU.
3. Select IF 1 with FUNCTION ( / ) key
4. Press BLUE key during IF 1 is highlighted, IF 1 and IF 2 values
are adjusted automatically by software.
5. If the standard is L-prime, IF 3 and IF 4 values are adjustment
automatically when BLUE key is pressed during IF 1 is
highlighted.
No. 52084
AV-29BF11ENS
AV-29BF11EPS
AV-29BF11EES
Description
FOCUS VR
SCREEN VR
Description