POST Error Messages
Error Code
170-EISA Expansion
Device Not
Responding
172-EISA
Configuration
Nonvolatile Memory
Invalid
172-1 Configuration
Nonvolatile Memory
Invalid
173-EISA Slot ID
Mismatch
174-EISA
Configuration/Slot
Mismatch Device Not
Found
175-EISA
Configuration/Slot
Mismatch Device
Found
176-Slot with Not
Readable ID Yields
Valid ID
* L= Long
S = Short
Continued
Audible
Beeps*
None
EISA Expansion board
failure
None
Nonvolatile configuration
corrupt or jumper
installed.
None
Nonvolatile configuration
corrupt.
None
Board replaced,
configuration not updated.
None
EISA board not found.
None
EISA board added,
configuration not updated.
None
EISA board in slot that
should contain an ISA
board.
Writer: Project: Diagnostic Tools Comments:
File Name: O-ch11.doc Last Saved On: 4/22/97 1:11 PM
Probable Source of
Problem
Contact your service
provider.
Run the System
Configuration Utility
and correct.
Run the System
Configuration Utility
and correct.
Run the System
Configuration Utility
and correct.
Run the System
Configuration Utility
and correct.
Run the System
Configuration Utility
and correct.
Run the System
Configuration Utility
and correct.
Compaq ProLiant 5000 Servers Reference Guide
11-3
Action