Mounting Recommendations - Vega Absolute SMART-SS0102 User Manual

Table of Contents

Advertisement

Smart-SS0102 / User Manual

MOUNTING RECOMMENDATIONS

The sensor should not be installed in places where there are intense air currents (near
fans, ventilation grids and air conditioners, heat sources), in rooms with a high level of dust,
cigarette smoke, steam, in wet and kitchen areas, in places of insects.
The coverage area of one sensor depends on the height of ceilings.
Height of the protected
room, m
up to 3,5
from 3,5 to 6,0
from 6,0 to 10,0
from 10,0 to 12,0
Smart-SS0102 structurally consists of two parts: device itself in the personal housing (1)
and the mounting platform (2).
1
During installation, the platform is first installed, all the necessary wires are connected
to it, if necessary. After that, it is necessary to align the mounting holes on the sensor housing
and the fasteners on the platform and turn the sensor clockwise until it clicks firmly.
Revision № 04 - 03 June 2021
The average area
controlled by a single
sensor, m
2
up to 85
up to 70
up to 65
up to 55
Platform fasteners
and corresponding
holes on the
sensor housing
Distance, m
Between
From a wall to
sensors
9,0
8,5
8,0
7,5
2
sensor
4,5
4,0
4,0
3,5
13