Any use of editorial, pictorial or layout composition of this publication without express written consent from Chattanooga Group of Encore Medical, L.P. is strictly prohibited. This publication was written, illustrated and prepared for print by Chattanooga Group of Encore Medical, L.P. ISO 13485 CERTIFIED...
CAUTION • Read, understand and practice the precautionary and operating instructions. Know the limitations associated with the Hydrocollator SS-2, M-2, M-4 Heating Units. Observe the cautionary and operational decals installed on the unit. • The thermostat is extremely sensitive and the slightest adjustment will alter the temperature several degrees.
Page 4
WARNING • Grounding the Hydrocollator SS-2, M-2, and M-4 Mobile Heating Unit: Make certain the unit is electrically grounded by plugging into a hospital grade electrical outlet with a ground terminal receptacle (U-ground outlet), 120 VAC only. Follow the National Electrical Code.
The operation of the unit may be restored by depressing the red button after the water/element temperatures have been allowed to cool. If the fault condition persists, please contact Chattanooga Group or an authorized agent.
TECHNICAL SPECIFICATIONS Hydrocollator ® Mobile Heating Units SS-2 Model Power Supply 110-120V~ 220-240V~ Rated Frequency 50/60Hz Power Consumption 1000 W Tank Capacity 49.32 Liters Temperature Range 160°F - 165°F (71°C - 74°C) Thermal Cut-out Temp 190°F ± 14°F (88°C ± 8°C) Accuracy +/- 10% Heating Up Time...
Page 9
TECHNICAL SPECIFICATIONS Hydrocollator ® Mobile Heating Units M-4 Model Power Supply 110-120V~ 220-240V~ Rated Frequency 50/60Hz Power Consumption 1500 W Tank Capacity 135.76 Liters Temperature Range 160°F - 165°F (71°C - 74°C) Thermal Cut-out Temp 190°F ± 14°F (88°C ± 8°C) Accuracy +/- 10% Heating Up Time...
SETUP Hydrocollator ® Mobile Heating Units Remove all of the contents inside the Hydrocollator and then replace the wire rack. Make certain the drain valve is closed before filling the tank with water. The tank should be approximately 3/4 full with packs removed. The tank may be filled from any standard type faucet.
TROUBLESHOOTING Hydrocollator ® Mobile Heating Units The following are solutions to minor performance problems. Only qualified personnel should service equipment problems. PROBLEM POSSIBLE CAUSE POSSIBLE SOLUTION 1. Breaker for electric circuit off. 1. Turn breaker ON. Unit Plugged In, 2. Thermostat not functioning. 2.
REPLACEMENT PARTS Hydrocollator ® Mobile Heating Units Model M-2 – Standard Cat. No. – 2402 w/packs Key* Part Description Part No. Element, Heating 120 Volt, 1000 Watt 10630 Hydraulic Thermostat 10631 Brkt. & Bulb Thermostat A/B Assembly (2 each)** 21023 22297 Caster 3 in 21259...
Page 13
REPLACEMENT PARTS Hydrocollator ® Mobile Heating Units Model SS-2 – Standard Cat. No. – 2302 w/packs Key* Part Description Part No. Element, Heating 120 Volt, 1000 Watt 10630 Hydraulic Thermostat 10631 Brkt. & Bulb Thermostat A/B Assembly (2 each)** 21023 Lid SS-2 22219 Caster 3 inch (4)
Page 14
REPLACEMENT PARTS Hydrocollator ® Mobile Heating Units Model M-4 – Standard Cat. No. – 2502 w/packs Key* Part Description Part No. Heating Element M-4, 120 Volt, 1000 Watt 20570 Hydraulic Thermostat 10631 Brkt. & Bulb Thermostat A/B Assembly (2 each)** 21023 22348 Caster 3 in...
Page 15
REPLACEMENT PARTS Hydrocollator ® Mobile Heating Units Model SS-2 220-240 VOLT – (Low Water) Cat. No. – 2307 w/packs Cat. No. – 2309 w/o packs Key* Part Description Part No. Element, Heating, 240V~ CE 22245 Thermostat, Hydraulic 10631 Lamp, Pilot, Green 22146 Cord Set (Country Specific) Switch...
Page 16
REPLACEMENT PARTS Hydrocollator ® Mobile Heating Units Model M-2 220-240 VOLT – (Low Water) Cat. No. – 2407 w/packs Cat. No. – 2409 w/o packs Key* Part Description Part No. Element, Heating, 220 Volt~, 1000 Watt 22245 Thermostat, Hydraulic 10631 Lamp, Pilot, Green 22146 Cord Set (Country Specific)
Page 17
REPLACEMENT PARTS Hydrocollator ® Mobile Heating Units Model M-4 220-240 VOLT – (Low Water) Cat. No. – 2506 w/packs Cat. No. – 2508 w/o packs Key* Part Description Part No. Element, Heating, 240 Volt~, 1500 Watt 22246 Thermostat, Hydraulic 10631 Lamp, Green, 1607-5107, 220-240 Volt~ 22146 Cord Set (Country Specific)
MAINTENANCE Hydrocollator ® Mobile Heating Units Care and Cleaning The Hydrocollator is equipped with an immersion type heating element and a hydraulic capillary type thermostat which evenly maintains the HotPac temperature in the water and provides a ready supply of heated packs.
Page 19
The pack should be replaced when it reaches this state. Original replacement Hydrocollator HotPacs may be ordered from an authorized Chattanooga Group dealer. NOTE: If HotPacs are to be stored for extended periods, they may be placed - while wet - in plastic bags and...
WARRANTY Hydrocollator ® Mobile Heating Units Chattanooga Group ("Company") warrants that the Hydrocollator Models SS-2, M-2, and M-4 Heating Units ("Products") are free of defects in material and workmanship. This warranty shall remain in effect for one year from the date of original consumer purchase. If these Products fail to function during the...