Do you have a question about the KITCHENAIRE DSS693 and is the answer not in the manual?
Questions and answers
Bryan
February 13, 2025
How to connect this iterm
1 comments:
Mr. Anderson
February 13, 2025
The Defy KITCHENAIRE DSS693 stove must be installed by a licensed electrician. It has a ‘Y’ type supply cord connection and must be correctly connected and safely earthed. The rated current is printed on the serial number label on the stove’s upper back panel. The appliance must be connected to the mains through an all-pole isolating switch with a minimum clearance of 3 mm in all poles. A means for disconnection must be provided in the fixed wiring. Electrical connection should not be done through an earth leakage system, and installation must comply with S.A.N.S. 10142 standards.
Need help?
Do you have a question about the KITCHENAIRE DSS693 and is the answer not in the manual?
Questions and answers
How to connect this iterm
The Defy KITCHENAIRE DSS693 stove must be installed by a licensed electrician. It has a ‘Y’ type supply cord connection and must be correctly connected and safely earthed. The rated current is printed on the serial number label on the stove’s upper back panel. The appliance must be connected to the mains through an all-pole isolating switch with a minimum clearance of 3 mm in all poles. A means for disconnection must be provided in the fixed wiring. Electrical connection should not be done through an earth leakage system, and installation must comply with S.A.N.S. 10142 standards.
This answer is automatically generated