Washing Results - Siemens SN65HX01CA User Manual

Table of Contents

Advertisement

aus Troubleshooting
Fault
E:61-02 will light up altern-
ately.
E:90-01 will light up altern-
ately.
A different error code ap-
pears in the display window.
E:01-00 to E:90-10

Washing results

Fault
Tableware is not dry.
46
Cause
Cover of the wastewater
pump is loose
Mains voltage is too low.
A technical fault is present.
Cause
No rinse aid used or dosage
set too low.
Programme or programme
option has no drying phase,
or the drying phase is too
brief.
Troubleshooting
Secure the cover of the "Wastewa-
ter pump " → Page 55 so it clicks
into position.
This is not a fault on the appliance.
Contact an electrician.
1.
Have the mains voltage and elec-
2.
trical installation checked by an
electrician.
Press .
1.
Unplug the appliance or switch off
2.
the fuse.
Wait at least 2 minutes.
3.
Insert the mains plug of the appli-
4.
ance in a socket or switch on the
fuse.
Switch the appliance on.
5.
If the problem occurs again:
6.
Press ⁠ .
Turn off the water tap.
Pull out the mains plug.
Contact "Customer Service"
→ Page 56 and give the er-
ror code.
Troubleshooting
Add "Rinse aid" → Page 28.
1.
Set the amount of rinse aid to be
2.
dispensed.
→ "Setting the amount of rinse aid",
Page 29
Select a programme with drying,
e.g. intensive, strong or ECO pro-
gramme.
Some option buttons decrease the
drying result, e.g varioSpeed.