Vaillant AtmoMAG 4/1 Z Series Installation And Maintenance Instructions Manual page 25

Hide thumbs Also See for AtmoMAG 4/1 Z Series:
Table of Contents

Advertisement

Min. permissible water pressure
P
when the temperature se-
w min.
lector is positioned at "warm"
Min. permissible water pressure
P
when the temperature se-
w min.
lector is positioned at "hot"
Flue gas temperature at max. heat
output
Flue gas temperature at min. heat
output
Min. chimney draught
Min. chimney draught when using
a thermal flue non-return flap
Domestic hot water volume at the
"hot" temperature selector posi-
tion
Domestic hot water volume at the
"warm" temperature selector posi-
tion
Max. heat input (in relation to the
net calorific value H
)
i
Min. heat input (Q
)
min.
Max. heat output (P
)
max.
Min. heat output (P
)
min.
Control range
Max. permissible water pressure
P
w max.
Min. permissible water pressure
P
when the temperature se-
w min.
lector is positioned at "warm"
Min. permissible water pressure
P
when the temperature se-
w min.
lector is positioned at "hot"
Flue gas temperature at max. heat
output
Flue gas temperature at min. heat
output
Min. chimney draught
Min. chimney draught when using
a thermal flue non-return flap
Technical data – Natural gas G20
Gas flow rate at max. heat output
Gas connection pressure
Number of burner jets
Burner jet
Burner pressure
Air requirement for combustion at
max. heat input
Air requirement for combustion at
min. heat input
CO₂ content at max. heat output
0020271943_00 atmoMAG Installation and maintenance instructions
MAG 114/1 Z(E-
MAG 114/1 Z(E-DE)
BE/FR)
27 kPa
27 kPa
(270 mbar)
(270 mbar)
13 kPa
13 kPa
(130 mbar)
(130 mbar)
200 ℃
200 ℃
105 ℃
105 ℃
1.5 Pa
1.5 Pa
10.0 Pa
10.0 Pa
MAG 144/1 Z(E-BE)
MAG 144/1 Z(E-DE)
3.2 ... 7.0 l/min
3.2 ... 7.0 l/min
6.2 ... 14.0 l/min
6.2 ... 14.0 l/min
27.7 kW
27.7 kW
9.7 kW
9.7 kW
23.1 kW
23.1 kW
8.3 kW
8.3 kW
8.3 ... 23.1 kW
8.3 ... 23.1 kW
1.3 MPa
1.3 MPa
(13.0 bar)
(13.0 bar)
38 kPa
38 kPa
(380 mbar)
(380 mbar)
19 kPa
19 kPa
(190 mbar)
(190 mbar)
185 ℃
185 ℃
90 ℃
90 ℃
1.5 Pa
1.5 Pa
10.0 Pa
10.0 Pa
MAG 114/1 Z(E-
MAG 114/1 Z(E-DE)
BE/FR)
2.30 m³/h
2.30 m³/h
1.7 ... 2.5 kPa
1.7 ... 2.5 kPa
(17.0 ... 25.0 mbar)
(17.0 ... 25.0 mbar)
24
24
0.85 mm
0.85 mm
1.12 kPa
1.12 kPa
(11.20 mbar)
(11.20 mbar)
38.77 m³/h
38.77 m³/h
30.62 m³/h
30.62 m³/h
6.30 %
6.30 %
MAG 114/1 Z(LL-
MAG 114/1 Z(P-
DE)
BE/FR)
27 kPa
27 kPa
(270 mbar)
(270 mbar)
13 kPa
13 kPa
(130 mbar)
(130 mbar)
200 ℃
200 ℃
105 ℃
105 ℃
1.5 Pa
1.5 Pa
10.0 Pa
10.0 Pa
MAG 144/1 Z(LL-
MAG 144/1 Z(P-BE)
DE)
3.2 ... 7.0 l/min
3.2 ... 7.0 l/min
6.2 ... 14.0 l/min
6.2 ... 14.0 l/min
27.7 kW
27.7 kW
9.7 kW
9.7 kW
23.1 kW
23.1 kW
8.3 kW
8.3 kW
8.3 ... 23.1 kW
8.3 ... 23.1 kW
1.3 MPa
1.3 MPa
(13.0 bar)
(13.0 bar)
38 kPa
38 kPa
(380 mbar)
(380 mbar)
19 kPa
19 kPa
(190 mbar)
(190 mbar)
185 ℃
185 ℃
90 ℃
90 ℃
1.5 Pa
1.5 Pa
10.0 Pa
10.0 Pa
MAG 114/1 Z(LL-
MAG 114/1 Z(P-
DE)
BE/FR)
2.30 m³/h
2.30 m³/h
1.7 ... 2.5 kPa
1.7 ... 2.5 kPa
(17.0 ... 25.0 mbar)
(17.0 ... 25.0 mbar)
24
24
0.85 mm
0.85 mm
1.12 kPa
1.12 kPa
(11.20 mbar)
(11.20 mbar)
38.77 m³/h
38.77 m³/h
30.62 m³/h
30.62 m³/h
6.30 %
6.30 %
Appendix
25

Advertisement

Table of Contents
loading