Connecting the flue pipe

Use a flue pipe with the diameter that is specified in the
technical data to connect the product to a flue system
that has a natural draught (hearth).
Insert the flue pipe (1) into the flue pipe connection (2) on
the down-draught diverter.
6

Start-up

6.1

Carrying out the initial start-up

Initial start-up must be carried out by a customer service
technician or a qualified competent person.
Remove the product casing (→ Page 11).
When starting up the unit, proceed in accordance with
the attached checklist.
Commissioning checklist (→ Page 21)
6.2

Gas conversion

Applicability: Except Belgium
1.
Observe the applicable national regulations.
2.
To convert the gas, use only Vaillant conversion sets or
Vaillant spare parts.
3.
Follow the instructions contained in the documentation
that is supplied with the conversion sets or spare parts.
6.3
Checking that the flue gas sensor works
correctly
If the flue system is fully or partially blocked or the local air
pressure conditions restrict the smooth flue system, the flue
gas sensor registers an increase in temperature and inter-
rupts the gas supply.
Check that the flue gas sensor is working correctly, as de-
scribed below.
0020271943_00 atmoMAG Installation and maintenance instructions
1
2
Start up the product with the product casing attached.
Turn the temperature selector (1) clockwise as far as it
goes and turn the rotary power switch (2) anti-clockwise
as far as it goes in order to set the lowest water volume
and the maximum gas volume.
Open a hot water tap.
Ensure that the water pressure is at least 0.13 MPa
(1.3 bar) during the test.
Operate the product until a steady state is reached (ap-
prox. 10 minutes).
Block off the flue gas route with a Vaillant flue gas re-
strictor, for example. Also observe the documentation
enclosed with the flue gas restrictors.
The flue gas sensor must automatically interrupt the
gas supply within two minutes.
Close the hot water tap.
Allow the flue gas sensor to cool for at least 15 minutes.
Start up the product again.
If the start-up does not work or the product is repeatedly
blocked by a safety device, check the product or contact
Vaillant Customer Service.
In this case, shut down the product.