30
en | Technical data
10
Technical data
PMX-4R24 24 Zone Router
Audio inputs (100 V)
•
•
•
Audio outputs (100 V)
•
•
•
CONTROL IN
•
CONTROL OUT
•
•
Interfaces
•
DC power input
Power consumption
Maximum supply current
Operating temperature
Electromagnetic environment
Product dimensions (Width ✕ Height ✕
Depth)
Net weight
Shipping weight
18-Jun-2015 | 03 | F01U306895
Max. voltage
Max. current
Max. power
Max. voltage
Max. current
Max. power
Control inputs
Control outputs
Control relay
CAN BUS port
Operation manual
PROMATRIX 6000 Router including routing
and supervision
AMP IN: 4 ✕ 6-pin port
120 V
eff
7.2 A
500 W
SPEAKER OUT: 4 ✕ 12-pin port
120 V
eff
7.2 A
500 W
4 ✕ 10-pin port
•
10 supervised inputs (0–24 V, U
V)
•
10 isolated inputs(Low: U ≤ 5 V DC;
High: U ≥ 10 V DC, U
4 ✕ 10-pin port
24 Low Power outputs (open collector, U
32 V, I
= 40 mA)
max
2 (NO/NC relay contacts, U
1 A)
2 ✕ RJ-45, 10 to 500 kbit/s (for controller,
router, amplifier connection)
21–32 V DC
5–60W
•
Standby < 250 mA
•
Idle/Announcment/Alert < 800 mA
-5 °C to 45 °C
E1, E2, E3
19", 2 HU, 483 ✕ 88.2 ✕ 375 mm
8.2 kg
9.7 kg
Promatrix 6000 Router
= 32
max
= 32 V)
max
=
max
= 32 V, I
=
max
max