This guide must be kept available for reference at all times. DISCLAIMER PRIVACY Inasmuch as RJG, Inc. has no control Designed and developed by RJG, Inc. over the use to which others may put Manual design, format and structure this material, it does not guarantee that copyright 2020 RJG, Inc.
The Lynx™ 50‑inch stroke/velocity sensor LE‑R‑50‑REVB is a molding machine‑mountable, linear position/velocity sensor designed for use with the RJG, Inc. eDART® and CoPilot® systems. The stroke/ velocity sensor can be used to monitor standard screw position and speed on most injection molding machines.
Read all instructions before installing The stroke/velocity sensor cable NOTES must enter the cable bushing hardware and related components. Contact straight to eliminate wear on the RJG, Inc. Customer Support for any cable prevent erroneous readings. questions regarding installation. Follow...
MOUNTING Mount the LE‑R‑50‑REVB on the molding machine injection unit sled using the two included 10‑24 x 2” cap screws. Lynx™ 50-Inch Stroke/Velocity Sensor LE-R-50-REVB | Product Manual...
Mount adapter plate on the molding the LE‑R‑50‑REVB as a replacement for machine injection unit sled using the four the LE‑R‑50‑REVA. Contact RJG to order a included 8‑32 x 1/2” screws in place of template to create the adapter plate. the previous LE‑R‑50‑REVA monting plate.
INSTALLATION SPECIFICATIONS (continued) CONNECTIONS Strain‑relieve the Lynx cable so The LE‑R‑50‑REVB is connected to the NOTES that movement of the sled does not eDART or CoPilot system with a single Lynx place strain on the LE‑R‑50‑REVB cable (CE‑LX5‑4M‑F90) featuring a 90° connector.
ALTERNATE INSTALLATIONS In the event that the recommended installation method is not possible, the LE‑R‑50‑REVB may be installed using either the preferred alternate installation, or if also not possible, the alternate installation. Do not use either of the following two methods if the recommended installation method is possible.
CLEANING the same results as those described here will be obtained. Nor does RJG, Inc. Keep the stroke/velocity sensor’s cable guarantee the effectiveness or safety clean and free from debris to ensure a long of any possible or suggested design for service life.
TROUBLESHOOTING COMMON INSTALLATION ERRORS 2. Cable is Angled 1. Cable Interference The stroke/velocity sensor is installed so The stroke/velocity sensor is installed that the cable exit/enters the sensor body so that there is interference along the at an angle instead of straight ( cable path.
CUSTOMER SUPPORT Contact RJG’s Customer Support team by phone or email. RJG, Inc. Customer Support P: 800.472.0566 (Toll Free) P: +1.231.933.8170 email: CustomerSupportGroup@rjginc.com www.rjginc.com/support Lynx™ 50-Inch Stroke/Velocity Sensor LE-R-50-REVB | Product Manual...
RELATED PRODUCTS COMPATIBLE PRODUCTS LYNX CABLES CE‑LX5 The Lynx sensor cable ( at right) is a polyeurethane‑coated cable suited for the heat and stress found in injection molding environments. The cable is available in lengths from 11.8– 472.4” (0,3– 12 m), and can be ordered with straight or 90°...